Instructions

b) Standard wiring for a single code lock connected to a master
system
In this example, the green and red LEDs are connected. These are used to indicate the
outputs, alarm, program mode and other features.
Refer to the instructions for example 1.
Output 2 is used to enable/disable the alarm. Refer to the instructions for the connected
security system. Note the output type, maximum currents/voltages, circuit type (NO or NC)
and start/stop features.
Connect the outputs on the tamper monitor to a 24-hour NC security system input and the
emergency code output on the corresponding NO input.
Connect all security systems to a common GND (output 15) to prevent malfunctions.
ELECTRIC LOCK
SYSTEM
TERMINALS
DOOR SENSOR
DOOR OPENER
CABLE HARNESS
EMERGENCY CODE - OUTPUT
RED LED
ALARM STATUS INDICATOR
GREEN LED
ALARM STATUS INDICATOR
TAMPER MONITOR
OUTPUT 2
ENABLES/DISABLES THE ALARM
WHITE/ORANGE
YELLOW GREEN
PURPLE
BLUE
WHITE/BROWN
YELLOW
LIGHT BLUE
GREEN
GREY
BLACK
RED