Instructions

b) Door sensor
When a position sensor (NC - typical magnet sensor) is connected to the door, the code lock can
beconguredtodothefollowing:
Automatically disable access
The sensor contact is broken when the door is opened. The outputs on the door lock are
disabled to prevent unauthorized access, even when the preset timer has not elapsed.
Forced door alarm
The code lock triggers an alarm when the sensor contact is broken without using the door
opener or a correct access code. The alarm will sound for 60 seconds, or until a correct ac-
cess code is entered. Use program code 80 to enable the alarm.
Open door alarm
The code lock triggers an alarm if the door is not closed within the preset time. Use program
code9tocongurehowlongthedoorcanstayopenbeforethealarmgoesoff(1–999sec-
onds).
Communication between code locks:
Output 14 is switched to GND when the door is opened. This prevents other code locks from
accessing the door.
MAGNETIC
DOOR CONTACT
DOOR SENSOR
45