Instructions

........................................................1 0 user codes outputs 3 (user 0-9), automatic or manual
code entry
Single user ...................................... 1 user code per output and feature, automatic or manual
code entry
User code combinations
Multiple users ................................. 111110000 possible combinations
(4–8 digits per user code)
Single user ...................................... 10000 possible combinations
(4 digits)
Inputs / Sensor inputs
T4 door opener ............................... NC input, can be switched to GND(-) with an NC switch.
T7 door sensor ............................... NC input, can be switched to GND(-) with an NC switch.
13 Inhibiting input ........................... NO input, can be switched to GND(-) with an NO switch.
Switching outputs
Output 1 .......................................... Integrated circuit with maximum 3 A / 12 V/DC current (fail
secure or fail safe).
Output 2 .......................................... Potential-free NC or NO output with maximum 1 A / 24 V/
DC current.
Transistor outputs ........................... Output 3, emergency code output, communication and
output 8
These are open collector outputs for NPN transistors. The outputs are switched to
GND (-) when they are activated. Maximum 100 mA/24 V/DC
Tamper monitor ............................... Potential-free NC output with maximum 50 mA / 24 V/DC
current.
Keypad reset: The keypad will be reset if the interval between key presses exceeds
10 seconds, or the entire code is not entered within 30 seconds.
Ambient conditions .........................Operating temperature: -20 to +70 °C
Ambient humidity ............................ 5–95% relative humidity (non-condensing)
Dimensions (H x W x L) ..................117 x 72 x 42 mm
Weight ............................................0.14 kg (without packaging)
Minor changes may be made to the product design, but these will not affect the features de-
scribed in these instructions.
49