Full Product Manual

17
The inverter can be set to output 50Hz or 60Hz using this switch
SW 5 (Battery/AC Priority):
When the inverter is set to battery priority (Position 1) it will invert power from the
battery bank to the AC outlets until the low voltage set point is reached. If there is an AC
source connected while under battery priority it will charge the battery after the low
voltage is reached and use the AC source to power the AC outlets. When the battery is
fully charged, the inverter will switch to battery power.
When choosing AC priority (Position 0) the battery power will only be used when there
is no shore power connected to the inverter. Once AC power is connected the inverter
will start charging the battery bank. If shore power is present for 15 continuous days,
then the inverter will use the battery bank for one cycle. This cycle is used to prolong
battery life.
LED Modes
Status
Function
Power
Saver
Over
Load
Over
Temp
Float
Charge
Fast
Charge
Inverter
Mode
Shore
Power
Charge
Function
Constant
Current
Charge
-
-
-
-
On
-
On
Constant
Voltage
Charge
-
-
-
-
Blinking
-
On
Float
Charge
-
-
-
On
-
-
On
Stand By
-
-
-
-
-
-
On
Inverter
Mode
Inverter
On
-
-
-
-
-
-
On
Power
Saver on
On
-
-
-
-
-
Power Saver Mode
The Renogy Inverter Charger has two working mode: “Power Saver Off” and “Power
Saver AUTO”
When the inverter is switched on to Power Saver Off the inverter will supply AC power
without any interruptions.
When the inverter is switched on to Power Saver AUTO the inverter will send a signal to
the AC loads for 250ms every 3 seconds and if an AC device (50W+) is connected the