inverter will start supplying power. NOTE: To activate this mode DIP switch 3 must be set
to position 1.
The idle consumption when using power saver mode is approximately 8 watts.
Audible Alarm
Indicator
Behavior
Over Temperature
Heat sink temperature ≥ 221 (Over
Temperature LED light on) beeps every
second
Low Battery Voltage
Inverter LED (Green) on and beeps every
second
High Battery Voltage
Inverter LED (Green) on and beeps every
5 seconds
Inverter Over-Load
Load >110% beeps every second
Fan Operation
Condition
Enter Condition
Leave Condition
Fan Speed
Temperature
149≤ T < 185
T ≤ 140 or T ≥
185
50%
T > 185
T ≤ 176
100%
Charging Current
20%< I ≤ 50%Max
I≤ 15% or I >
50%Max
50%
I > 50%Max
I ≤ 40%Max
100%
AC Load
30% ≤ Load < 50%
Load ≤ 20% or
Load ≥ 50%
50%
Load ≥ 50%
Load ≤ 40%
100%
Please allow a minimum of 6 inches of clearance around the inverters vents. Fan noise
level <60db at 1 meter.
Auto Gen Start