External Fusing
Fusing is a recommended in PV systems to provide a safety measure for connections
going from panel to controller and controller to battery. Remember to always use the
recommended wire gauge size based on the PV system and the controller.
NEC Maximum Current for different Copper Wire Sizes
#AWG
16
14
12
10
8
6
4
2
0
Max.
Current
10A
15A
20A
30A
55A
75A
95A
130A
170A
Technical Specifications
Model
RNG-INVT-1000-12V-C
RNG-INVT-2000-12V-C
Rated Power
1000W
2000W
Surge Power
2000W
4000W
Rated Voltage
12V
Rated Voltage Range
10V-16V
Input Voltage
DC ≥ 10V ± 0.5V
Over-Voltage Range
16V ± 0.5V
Low Battery Voltage Alarm
10.5V/11.0V
Output Waveform
Pure Sine Wave
Nominal Efficiency
>88% Peak
Power Factor
0.9-1.0
Battery Charging Current
5-25 A
15-45 A
Nominal Output Voltage
100-110-120VAC
Output Voltage Regulation
±10% RMS
Output Frequency
50/60Hz ±0.3Hz
THD
<10%
Input Voltage Waveform
Sine Wave (External AC Source)
AC Input Range
90-135 VAC