Full Product Manual

22
AC Input Frequency
Range
57-65±0.3Hz for 60Hz
Low Voltage Disconnect
80V/90V±4%
Low Voltage Reconnect
90V/100V±4%
High Voltage Disconnect
140V±4%
High Voltage Reconnect
135V±4%
Short Circuit Protection
(AC Output)
Circuit Breaker
Bypass Breaker Rating
20A
30A
Dimension
15 x 8.5 x 7 in
381 x 215.9 x 177.8 mm
20.5 x 8.5 x 7 in
520.7 x 215.9 x 177.8 mm
Weight
35.27 lbs.
40.9 lbs.
Operating Temperature
14°F-122°F
AC Sockets
2
4
Charging Parameters
Number
Battery Type
Boost Voltage
Float Voltage
1
Gel 1
14.0V
13.7V
2
A.G.M 1
14.1V
13.4V
3
A.G.M 2
14.6V
13.7V
4
Sealed Lead Acid
14.4V
13.6V
5
Gel 2
14.4V
13.8V
6
Flooded Lead Acid
14.8V
13.8V
7
Calcium (Open)
15.1V
13.6V
8
Equalization
15.5V for 4 hrs.
Renogy reserves the right to change the contents of this manual without notice.
Revision: 06/19/2017