Full Product Manual

11
Ensure installation follows the following guidelines:
1. Cool, dry, well-ventilated areaHeat is the worst enemy for electronic
equipment. Inverters must be in an area where the fans are not blocked or where
they are not hit directly by the sun. They should be in an area free of any kind of
moisture and allow for clearance of at least 10” around the unit to provide for
adequate ventilation.
2. Protection against fire hazardthe unit should be away from any flammable
material, liquids, or any other combustible material. The unit can spark and the
consequences could be severe.
3. Close proximity to battery bankprevent excessive voltage drop by keeping the
unit close to the battery bank and having a properly sized wire going from the
battery bank to the inverter.
4. WARNING: Do not install the inverter in the same compartment as the battery
bank because it could serve as a potential fire hazard.
5. Limiting electromagnetic interference (EMI)ensure the inverter is firmly
grounded to a building, vehicle, or earth grounded. Keep the inverter away from
EMI receptors such as TVs, radios, and other audio/visual electronics to prevent
damage/interference to the equipment.
6. Secure inverterthe inverter could be stand alone or mounted using the outlying
terminals on the inverter.
WARNING: The inverter should never be mounted vertically on a vertical
surface since it would present a hazard for the fan opening which is crucial
for cooling the inverter.
Sizing a Battery Bank
1. Determine the amount of Watts (Amps * Volts) for the load, and how long
the load needs to operateeach electrical appliance has a technical
specifications indicating the watts, or the volts and amps required for operation.
2. Estimate load run-timedetermining a battery size relies heavily on load watts
and run-times. Most loads will not be constant, so estimations are key.
3. Utilize the formula Watts = Volts * Amps
4. Determine Amps used for how many hours Amp-hour (Ah)