Full Product Manual

17
Short Circuit Indicator
(AUDIBLE ALARM)
If the inverter experiences an internal
short circuit, it will sound the alarm and
turn on the red indicator.
Inverter Troubleshooting
Indicator
Troubleshoot
Under Voltage or Over
Heat Protection
Use a multi-meter to check the voltage of the battery.
Make sure the battery voltage is not below the rated
specification of the inverter. The inverters have an input
requirement of at least 11 ± 0.5 volts. Disconnect battery
if necessary.
Relocate inverter to cooler area if all else does not work.
Over Voltage Protection
Use a multi-meter to check the voltage of the battery.
Make sure the battery voltage is not exceeding the rated
specification of the inverter. The maximum input voltage
should not be exceeding 16 ± 0.5 volts.
Over Load protection
Turn off the inverter and check the rated specification for
the electronic device(s). Be sure to check that the watts
(volts * amps) does not exceed the specification for the
inverter. Be very cautious if using power strips as they
can be clear indicator for overload for inverters.
Also, some electronic devices may require an initial high
power surge start. Make sure all AC appliances are off
before turning on the inverter’s power switch.