Full Product Manual

18
Short Circuit
A short might occur down the DC line connecting to the
inverter. Check the battery connections going to the
inverter and ensure that there is continuity. In the event
that there is an in-line fuse installed, check to make sure
the fuse has not blown. Reset the inverter by turning it off
for approximately 5 seconds and powering it back on.
Other Considerations
Radio or television
experience some
interference.
Inverters contain internal switching devices that can
generate electromagnetic interference (EMI). Though
this cannot be entirely eliminated, it is recommended that
inverters are properly grounded, and that they are
located as far away from EMI receptors such as radios,
televisions, and other audio/visual devices.
Battery cables are
connected to the
inverter but it does not
power on.
The inverter needs a minimum of 11 volts to operate.
Use a multi-meter to make sure the battery levels are
suitable for operation. If all checks out, check the wire
connections and inspect for any breaks or tears.
AC shuts down after
some use
Users should be weary of the electronic devices they are
powering on. Many electronics have an initial power
surge that might trigger the inverter into overload and
hence shutting down the operation. If this occurs, reduce
the load and check the connections and power
specifications. Reset the inverter by turning it off for
about 20 seconds and powering it back on