Manual

05 Custom Battery Type /User Mode
21
Maximum charging voltage
for Lithium battery. When
the voltage reaches the set
voltage, charging will stop.
V
BATT
If the preset battery options are not compatible with your system, you will need to custom the
charging by following the next steps.
2.Go to Program 94 to determine whether the custom battery is a Lithium or non-lithium
battery, Refer to the chart below:
1. Set the battery type to b-0. By default this unit is preset to boost at 14.3V and Float at
13.7V.
3.If choosing a custom lithium battery, make sure the previous Program 94 is at ALb.
Otherwise if programming a non-lithium battery skip to Step 4.
a.After setting Program 94, go to Program 26 to select the maximum charging voltage for your
custom lithium battery. Please Note when the voltage set point is reached, the custom lithium
battery will stop charging
User-defined
(
default fast V 14.3
Floating V 13.7)
For Charging to be
accurate, Temperature
Sensor must be connected.
Program
Number
Parameter
Setting
Description
If User-Defined is selected ,user can set the
battery type in program94
If selected, battery charge voltage and
battery low open charging can be set up in
program 26,27
Program
Number
Parameter
Setting
Description
Other battery
Lithium battery
If selected ,battery charge voltage can be set
up in program 26,27
If User-defined is selected in program 94,this program can be set
the maximum charging voltage.Setting range is from 13.0V-15.5V
Selection of battery type
Program
Number
Parameter
Setting
Description
26
94