The PCL inverter will demonstrate the fault code.
25
25 Record Fault Code
Refer to Program 5 for modifying this setting.
26
26 Boost Charging
This program determines the cut-off voltage range for the PCL inverter charger battery input.
Upon reaching this voltage, the PCL inverter will cut off operation until the battery can go above
this voltage level.
This setting will not be modifiable if users choose a pre-set battery voltage.
NOTE
Bulk charging voltage(C.V
voltage)
If User-defined is selected in program 94,this program
can be set the maximum charging voltage. Setting
range is from 13.0V-15.5V
If User-defined is selected in program94,this program can
be set up. Setting range is from
program 94
Maximum charging voltage
for Lithium battery. When
the voltage reaches the set
voltage, charging will stop.
V
BATT
V
BATT
Refer to Program 5 for modifying this setting.
27
27 Float Charging
29 Low DC Cut-off Voltage
This setting will not be modifiable if users choose a pre-set battery voltage.
This value must be lower than Program 98: Low Battery Voltage Warning
NOTE
NOTE
If User-defined is selected in program 94,this program can
be set up.Setting range is from 13.0V to 15.0V for 12V
Floating charging voltage
If User-defined is selected in program 94,this program can
be set up.Setting range is from 12.0V to 14.0V for 12V
Battery low voltage open
charging(for lithium battery)