How to Guide

19
Power Mode
Solid Power On
Power LED AC Load ≤ 50W
Power On
AC Load > 50W
Normal
Pulsing Idle Power OnECO
DIP Switches
The DIP switches allow you to control the inverter’s ac output frequency or power up in an
ECO power saving mode. For DIP switch changes to take effect you must:
You can change your AC output frequency between 50Hz or 60Hz depending on your
location. By default, the USA uses 60Hz.
1.Shut down the inverter via power button or remote
2.Make the desired dip switch change
3.Power On the inverter via power button or remote
4.DIP Switch changes have taken effect
Frequency DIP Switch
ECO mode is a battery saver mode. When on, the inverter will search for a load by sending
a pulse every 2~3 seconds to the AC outlets. The Power LED will also pulse. Loads that are
50Watts or less will not be powered on and the inverter will remain in this mode until 50W or
greater is detected or until it is manually shutdown.
ECO Mode