Quick Guide

0808
Installation
Service Battery Wiring
z
Please read the user manual of the service battery carefully before installation.
z
Identify the polarity (positive and negative) on the cables used for the batteries. A reverse
polarity contact may damage the unit.
z
Select a suitable wrench or other tool when tightening the battery bolts to their rated
speciļ¬cation.
z
Please ensure that the Anderson connectors are fully seated and/or the ring terminals are
securely connected.
Battery Scenario A: REGO Battery Kit
z
Please read the user manual of System Combiner Box carefully before wiring.
z
If the devices are connected to the Anderson connectors of the System Combiner Box, please
install a 160A NH fuse in the top NH fuse disconnect switch.
z
If the Anderson PP75 to Ring Terminal Adapter Cable is used to connect with the System
Combiner Box, please refer to the user manual of REGO 12V 60A DC-DC Battery Charger at
renogy.com for more detailed instructions.
z
If positive/negative busbars are used to connect with the normal service battery, please
refer to the user manual of REGO 12V 60A DC-DC Battery Charger at renogy.com for more
detailed instructions.
input output
DC-DC Battery Charger
Output
STEP-3.1
Insert the Anderson 120
connector of the Battery
Adapter Cable (output) to the
System Combiner Box.