7.2 Battery charging function
The charging characteristics are referred to as IU0U characteristics.
1: I phase (bulk)
At the beginning of the charging process, the flat battery is charged with a
constant current (100 % charge current) until the battery voltage reaches
the charging end voltage. The charging current decreases when the battery
has reached this charging level.
2: U0 phase (absorption)
Now the absorption charging process (U0 phase) begins, where the duration
depends on the battery. The voltage remains constant (U0).
This phase is limited to a maximum of 3 hours to prevent overcharging the
battery while driving.
3: U phase (float)
Aer the U0 phase, the battery charger switches to the conservation charging
function (U phase).
U0 U
U
I
I
1
100 %
10 %
2 3
t
U/V
I/A