Installation Guide
Connect charging converter
19
Determine cable cross-section
The minimum cable cross-section depends on the maximum cable length:
9.1 Connect charging converter
Connect the charging converter as shown:
– Correct connection diagram: fig. , page 5
– Connecting the batteries: fig. , page 6
– Connect control line (I1): fig. , page 6
9.2 Connect accessories
Connect the accessory to the following contacts:
– Performance regulation (I2): fig. 5, page 3
– Temperature sensor: fig. 6, page 3
NOTE
Keep the distance to the body battery as short as possible.
Cable length Minimum cable cross-section/Fuse
2.5 mm² /
30 A
4 mm² /
40 A
6 mm² /
60 A
10 mm² /
80 A
DCC-1212-20
to the starter battery ≤7 m ≤11 m ≤16 m –
to battery structure ≤2 m ≤3.5 m ≤5 m –
DCC-1212-40
to the starter battery – ≤5.5 m ≤8 m ≤14 m
to battery structure – ≤1.5 m ≤2.5 m ≤4 m
DCC-1212-60
to the starter battery – – – ≤7 m
to battery structure – – – ≤2 m
NOTICE!
The charging converter must not be connected directly to the alternator.
NOTE - Performance regulation
To limit the output current of the charging converter to 5 A, a positive
control signal must be present at contact “I2” (fig. 5, page 3).
4
1
1
1
5
6