Installation Guide

Use charging converter
21
Set float voltage
You can use the DIP switches S3 and S4 toset theoat voltage in the U phase (float).
S
Set Charging mode voltage of Lithium-ion battery
Type 1
Type 2
et charging mode
You can set the charger mode using the S5 and sw itches.
S3 S4
Float voltage
12 V
WARNING! Danger of explosions!
Use only the charging mode appropriate for your battery type. If
necessary inquire at a specialist workshop.
ON ON
OF F ON
ON OFF
13. 2 V
13. 5 V
13. 8 V
OF F OFF
Charging mode of lead-acid battery
Charging mode of Lithium-ion battery
S5 Charger Mode
ON
OFF
ON ON
OF F ON
ON OFF
12.8 V
12.6 V
13. 0 V
OF F OFF
S3
Set to Type 2. Exit Type 1
Voltage/ Type Set S4
ON ON
OF F ON
ON OFF
14.2 V
14.6 V
14.4 V
14.0 VOF F OFF
S3 Voltage S4
!