Installation Guide

Technical data
23
Protective devices
DCC-1212-20 DCC-1212-40 DCC-1212-60
V21Transformation: 12 V
V21Nominal input voltage:
V61 V8Input voltage range:
Charging current:
V7.41 V2.31Charging voltage:
Output:
Residual ripple of output
voltage at rated current:
< 50 mV
eff
%09Efficiency up to:
A4.0 <Idle power consumption:
Ambient temperature for
operation:
–20 °C to +50 °C
Ambient humidity: 95% Non-condensing
Dimensions (W x D x H):
1.88kg 2.40kg1.33kg
500W 750W250W
40 A 60 A20 A
Weight:
Inspection/certification:
12V
High-voltage, low-voltage, reverse polarity
protection (internal fuse)
:tupnI
8 V:tuo-tuc egatlov-woL
10 VLow-voltage restart:
16 VHigh-voltage shutdown:
15.5 VHigh-voltage restart:
nwodtuhS:erutarepmeT
I ,seyShort-circuit protection:
pk
261*175*68 mm
311*175*68 mm
211*175*68 mm