Dimensions
Battery Charging Parameters
Battery Type GEL FLOODED
Over-voltage Warning 16 V 16 V
Charging Limit Voltage
Over-voltage Recover
15.5 V15.5 V
Boost Charge Voltage
Float Charge Voltage
Boost Return Voltage
Over-discharge Recover
Equalization Voltage
----- -----
----- -----
-----
14.8 V
14.6 V 14.6 V
13.8 V 13.8 V
13.2 V13.2 V
12.6 V 12.6 V
SEALED/AGM
16 V
15.5 V
14.2 V
13.8 V
13.2 V
12.6 V
LI (LFP)
16 V
15 V 15 V15 V 15 V
15.5 V
-----
-----
-----
----------
14.2 V
(User:12.6-16V)
13.2 V
12.6 V
Under Voltage Recover
12.2V
12.2V12.2V
12.3V
11.1V
11.1V11.1V
11.1V
12V
12V12V
12.1V
Under Voltage Warning
Over-discharge Warning
2 hours
Equalization Duration
-----
2 hours2 hours 2 hours
28 days
Boost Duration
Equalization interval
* Battery charging parameters in LI mode can be programmed using Renogy BT App.
** Default charging parameters in LI mode are programmed for 12.8V LFP battery.
Before using Wanderer to charge other types of lithium battery, set the parameters
according to the suggestions from battery manufacturer.
[ 0.7 in ]
17.3mm
[ 0.1 in ]
R2.3mm
[ 0.1in ]
1.0mm
[ 6.5 in ]
163.8mm
[ 1.8 in ]
44.7mm
[ 3.6 in ]
92.3mm
[ 4.3 in ]
109.6mm