To enter the programming interface simply press and hold the right arrow button. After entering
this feature press the Enter/Right button to switch between parameters. To change the
parameters, press the Up or Down button. To save the parameter press and hold the
Enter/Right button.
The charging parameter setting (Equalizing voltage, Boost voltage, Floating charging voltage,
over-discharge return voltage, Over-discharge voltage) are only available under the battery
“USER” mode. Press and hold the right arrow to enter the programming settings and continue
pressing the right arrow button until you see the desired voltage screen.
Battery charging parameters can also be programmed using the Renogy BT APP. Read the
corresponding user manuals for more information.
Programming Parameters
NOTE
Over-discharge voltage
Over-discharge
return voltage
Battery type System voltage Equalizing voltage
Float voltage
20