Icons Pattern Possible Causes Corrective Steps
Slow
Flash
CIG Output
Overcurrent/Short
Circuit
Disconnect the device from the CIG Port.
Remove the short circuit if the CIG Port is
shorted.
Check the current rating of the device. Stop
using the device if it draws current that ex-
LCD Display lit up to release the protection.
Connect the device with the appropriate cur-
rent rating to the CIG Port. Power can be re-
sumed.
Slow
Flash
AC Output
Overvoltage/
Undervoltage
Disconnect the devices from the AC Outlets.
Display lit up to release the protection.
Reconnect the devices to the AC Outlets.
Contact us for help if the icons persist.
Slow
Flash
AC Output
Overload/Short
Circuit
Disconnect the devices from the AC Outlets.
Remove the short circuit if the AC Outlets are
shorted.
Check the power ratings of the devices. Stop
using the devices if their power ratings are
higher than 800W.
Display lit up to release the protection.
Connect the devices with the appropriate
power ratings to the AC Outlets. Power can be
resumed.
Slow
Flash
Inverter High
Temperature
Check if the fan inlet and outlet are blocked.
Cool down PHOENIX to the room temperature.
Display lit up to release the protection. Power
can be resumed.