Installation guide

Installation Guide RN3000US Jan13
28
Two fasteners are required to secure each of the cross bar to a stud wall. The
fasteners must be fastened on the wood stud of the wall. Fastener holes of cross
bars must be aligned on vertical direction. The vertical distance
between cross
bars is 210mm. (Wood screws are provided however it is installer’s responsibility
to ensure fasteners to be appropriate for wall material.)
Mounting the bracket to the cross bars
Six M6 machine screws are required to secure the bracket to the cross bars.
Figure 4-7 Fasten the Bracket against Masonry Wall with Expansion Screws
1
2
345
6