SDS

D8040582 v 8.0
5. Fire-fighting measures
Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without suitable
training. Move containers from fire area if this can be done without risk. Use water
spray to keep fire-exposed containers cool.
Hazardous thermal
decomposition products
Specific hazards arising
from the chemical
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
Flammable aerosol. Runoff to sewer may create fire or explosion hazard. In a fire or if
heated, a pressure increase will occur and the container may burst, with the risk of a
subsequent explosion. Gas may accumulate in low or confined areas or travel a
considerable distance to a source of ignition and flash back, causing fire or explosion.
Bursting aerosol containers may be propelled from a fire at high speed.
Fire-fighters should wear appropriate protective equipment and self-contained breathing
apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Special protective
equipment for fire-fighters
Use an extinguishing agent suitable for the surrounding fire.
Extinguishing media
:
:
:
None known.
Suitable extinguishing
media
:
Unsuitable extinguishing
media
:
Special protective actions
for fire-fighters
:
6. Accidental release measures
Environmental precautions
Personal precautions, protective equipment and emergency procedures
:
:
No action shall be taken involving any personal risk or without suitable training.
Evacuate surrounding areas. Keep unnecessary and unprotected personnel from
entering. In the case of aerosols being ruptured, care should be taken due to the rapid
escape of the pressurized contents and propellant. If a large number of containers are
ruptured, treat as a bulk material spillage according to the instructions in the clean-up
section. Do not touch or walk through spilled material. Shut off all ignition sources. No
flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide
adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put
on appropriate personal protective equipment.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains
and sewers. Inform the relevant authorities if the product has caused environmental
pollution (sewers, waterways, soil or air).
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and
explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively,
or if water-insoluble, absorb with an inert dry material and place in an appropriate waste
disposal container. Dispose of via a licensed waste disposal contractor.
Small spill
:
Methods and materials for containment and cleaning up
For non-emergency
personnel
For emergency responders
:
If specialized clothing is required to deal with the spillage, take note of any information in
Section 8 on suitable and unsuitable materials. See also the information in "For non-
emergency personnel".
4/13
2/5/2020
Date of issue
:
SDS #
8125757_D8040582
(NA)
:
Code #
D8040582 v 8.0
: