Replacement Parts Guide
Form P-RG/RP/RBL, P/N 263984R2, Page 38
RBL; PGBL, (C)RGBL, RPBL 400, 800,
1200; & RPDBL 800, 1600 (2 sets)
RBL; PGBL, (C)RGBL, RPBL 400, 800,
1200; & RPDBL 800, 1600 (2 sets)
RBL; PGBL, (C)RGBL, RPBL 400, 800,
1200; & RPDBL 800, 1600 (2 sets)
A 16 x 16
B 16 x 25
C 12 x 25
D 12 x 30
PGBL, (C)RGBL, RPBL 500, 600;
RPDBL 1000, 1200 (2 sets)
PGBL, (C)RGBL, RPBL 500, 600;
RPDBL 1000, 1200 (2 sets)
PGBL, (C)RGBL, RPBL 500, 600;
RPDBL 1000, 1200 (2 sets)
PGBL, (C)RGBL, RPBL 700, 1050;
RPDBL 1400 (2 sets)
PGBL, (C)RGBL, RPBL 700, 1050;
RPDBL 1400 (2 sets)
PGBL, (C)RGBL, RPBL 700, 1050;
RPDBL 1400 (2 sets)
Filter Arrangements for 1" or 2" Disposable Filters (Options AW2 and AW7)
Filter Arrangements for 1" or 2" Disposable Pleated Filters (Options AW10 and AW11)
Filter Arrangements for 1" or 2" Permanent Filters (Options AW8 and AW9)
Blockoff Plates:
(1) P/N 106334;
(4) P/N 114337
Blockoff Plates:
(1) P/N 106332;
(4) P/N 114336
Blockoff Plates:
(1) P/N 106332;
(4) P/N 114336
Blockoff Plates:
(1) P/N 106334;
(4) P/N 114335
Blockoff Plates:
(1) P/N 106332;
(4) P/N 114337
Blockoff Plate:
(1) P/N 106333
Blockoff Plate:
(1) P/N 106334
Blockoff Plate:
(1) P/N 106334
Blockoff Plate:
(1) P/N 106332
Replacement Filters/Blockoff Plates for Model Series RGBL/RPBL and Blower Cabinet Model RBL
manufactured prior to 9/91
Filter
Code
Filter
Size
* 2"
Disposable
* 2"
Permanent
* 2"
Pleated
Unit Size and Quantity of Filters
Required
AW7 AW9 AW11 500 600 700/1050 400/800/1200
A 16 x 16 104101 104103 104109 -- -- -- 4
B 16 x 20 104097 101620 104110 4 4 -- 8
C 16 x 25 104099 101622 104112 4 4 8 --
Blockoff Plates
Code P/N "X"
1 106332 1-1/2" (38mm)
2 106333 2" (51mm)
3 106334 5/8" (16mm)
Filter Removal and Installation Instructions - Applies only to RGBL and RPBL Series manufactured prior to 9/91
Filter Removal
1. Remove screw (1) from the lter rack and
remove the retaining angle.
2. Rotate lter down and remove from unit. Slide
next lter over and rotate down and out. Repeat
for remaining lters in top row.
3. Remove screw (1) from lter rack and remove
retaining angle.
4. Rotate lter up and out of rack. Slide the next
lter over and rotate up and out. Repeat for
remaining lters in the row.
5-8. Repeat Steps 3 and 4.
9. See lter installation instruction label.
Filter Installation
1. Insert lters in the bottom row.
2. Replace retaining angle and
insert screws (1).
3. Insert lters in the next level.
4. Replace retaining angle and
insert screw (1).
5-7. Repeat Steps 3 and 4.
8. Replace retaining angle and
insert screws (2).
9. Replace lter cabinet door and
secure all latches and screws.
Replacement Filters/Blockoff Plates - currently manufactured "BL" Cabinets
Blockoff
Plate
A
A
A
A
B
B
B
B
B
B
B
B
Sizes 400/800/1200
3
2
2
2
C
C
C
C
C
C
C
C
Sizes 700/1050
3
2
2
2
C
C
C
C
B
B
B
B
Sizes 500/600
1
1
1
3
Filter
Filter
X
* If replacing 1" lters, replace with locally
supplied lters in the size and type listed.
Quantities are listed above by size,
arrangements are illustrated right, and
instructions below apply to both 1" and 2"
lters.
A 16 x 16
B 16 x 25
C 12 x 20
D 12 x 25
A 16 x 25
B 12 x 20
C 12 x 30
A 16 x 16
B 16 x 25
C 12 x 25
D 12 x 32
A 16 x 20
B 16 x 25
C 12 x 20
D 12 x 25
A 16 x 25
B 12 x 20
C 12 x 32
A 16 x 16
B 16 x 25
C 12 x 16
D 12 x 26
A 16 x 20
B 16 x 25
C 12 x 20
D 12 x 26
A 16 x 25
B 12 x 26