Replacement Parts Guide

Form P-RG/RP/RBL, P/N 263984R2, Page 41
Code
Model RPBL, RGBL, PGBL Sizes
500, 600 700, 1050 400, 800, 1200
Model (C)(H)RGB/RPB Sizes
75, 100,125 150, 175 200, 225 250, 300 350 400
Description
*Opt AU Construction P/N
570A
Coil Cabinet Top
2, 3, 11, 12,
13, 14
Single and
Double Wall
172314 172353 172354 172416 172419 172422
570B -- -- -- 172417 172420 172423
571 Top Filler (between top sections) -- -- -- 105629 105630 105631
572 Gasket for Top Filler (under 571) -- -- -- (2) 103608 (2) 103609 (2) 103610
573 Inner Top Support Insulation -- -- -- 172536 172535 172534
574 Inner Top Support -- -- -- 172482 172483 172484
575 Top Insulation Retainer 172365 172366 172367 (2) 172368 (2) 172400 (2) 172369
576 Top Insulation 172516 172517 172518 (2) 172519 (2) 172521 (2) 172520
577 Plenum Cabinet Top
11, 12, 13,
14
Single and
Double Wall
100063 100064 100065 100066 100067 100068
578 Gasket between Coil & Plenum Cabinet Tops 103605 103606 103607 103608 103609 103610
579 Plenum Cbnt Top Insulation Retainer 100253 100254 100255 100256 100257 100258
580 Plenum Cabinet Top Insulation 103592 103593 103594 103595 103596 103597
581 Coil Cabinet Door Assembly
2, 3, 11, 12,
13, 14
Single Wall 172501 172502 172503 (3) 172498 (3) 172499 (3) 172500
Double Wall 172337 172338 172339 172340 172341 172342
582 Small Coil Cabinet Door Assembly
Single Wall -- -- -- 174012 174013 174014
Double Wall -- -- -- 172343 172344 172345
583 Top of Split Access Door
2, 11, 12
Single and
Double Wall
172373 172374 172375 -- -- --
584 Insulation for Code 583 172525 172526 172527 -- -- --
585 Liner for Code 583 Double Wall 172486 172487 172488 -- -- --
586 Btm of Split Access Door
Single and
Double Wall
172370 172371 172372 -- -- --
587 Insulation for Code 586 172522 172523 172524 -- -- --
588 Liner for Code 586 Double Wall 172495 172496 172497 -- -- --
590 Extended Cabinet (Doghouse) Section Top
3, 13, 14
Single and
Double Wall
172326
591 Left Side of Extended Section 172325
592 Right Side of Extended Section 172324
593 Bottom of Extended Section 172327
594 Top Door of Extended Section 172460
595 Btm Door of Extended Section 172459
Parts Shipped Loose (not
illustrated) with a New Coil
Cabinet Option AU 2, 3, 11,
12, 13, or 14
Used to attach the coil cabinet
to the heat section; follow
instructions in the installation
manual.
RPBL, RGBL, PGBL Sizes
500, 600 700, 1050 400, 800, 1200
(C)(H)RGB/RPB Sizes
75, 100 125 150, 175 200, 225 250, 300 350 400
Description Qty P/N's and Lengths
Top/Btm Duct
Connectors
2
107426,
14"
107427,
16-3/4"
107428,
21-1/4"
107429,
27-3/4"
106338,
36"
106339,
41-1/2"
106340, 47"
Side Duct Connectors 2 106395, 19-1/2"
Sheetmetal Screws 8 105171, #14 x 3/4" lg
Left Side Filler Panel 1 172357
Right Side Filler Panel 1 172358
Top Filler Panel 1 172359 172360 172361 172362 172363 172364
Insulation 2 172546, 1" x 42" x 9"
Sheetmetal Screws,
#10 x 1/2" lg
(19)
11813
(19)
11813
(21)
11813
(22)
11813
(24)
11813
(25)
11813
(26)
11813
Rubber Gasket Strip,
3/32" x 1-1/8" x …>
1 103605, 34-5/8"
103606,
40-1/8"
103607.
45-5/8"
103608,
53-7/8"
103609,
59-3/8"
106310, 64-7/8"
Code
Model RPBL, RGBL, PGBL Sizes
500, 600 700, 1050 400, 800, 1200
Model (C)(H)RG/RP(B) Sizes
75, 100 125 150, 175 200, 225 250, 300 350 400
Description
*Opt AU Construction P/N
596 Top Inlet Side Panel
2, 3, 11,
12, 13,
14
Single and
Double Wall
172480 172440 172435 172436 172437 172438 172439
597 Bottom Inlet Side Panel 100036 100037 100038 100039 100040 100041 100042
598 Top Discharge Side Panel 172440 172435 172436 172437 172438 172439
599 Bottom Discharge Side Panel 100037 100038 100039 100040 100041 100042
600 Inlet Duct Flange Assembly 107394 107395 107396 107397 107398 107399 107400
601A
Corner Posts - Inlet End of Cabinet
172478 172306
601B 172479 172305
602
Horizontal Discharge Duct Flange
Assembly (not illustrated)
107395 107396 107397 107398 107399 107400
603 Center Post / Center Post Cover -- -- -- -- (2) 172461 / (2) 172462
604A
Corner Posts / Corner Post Covers -
Discharge End of Coil Cabinet
3, 13, 14
172306 / 172313
604B 172321 / 172311
605A
2, 11, 12
172306 / 172313
605B 172304 / 172311
606 Plenum Door Panel Assembly
11, 12,
13, 14
Single Wall (2) 172532
Double Wall (2) 172310
607 Plenum Cabinet End Panel Assembly
Single Wall 172504 172505 172506 172507 172508 172509
Double Wall 172346 172347 172348 172349 172350 172350
608 Plenum Cabinet Corner Post / Post Cover
Single and
Double Wall
(2) 172442 / (2) 172450
609 Filler between Plenum & Coil Cabinet (2)172451
610 Adjustable blockoff - coil cabinet
2, 3, 11,
12, 13,
14
Single and
Double Wall
174683
611 Adjustable blockoff - coil cabinet 179336
612 Adjustable blockoff gasket (2) 174856 (2) 174857 (2) 174858 (2) 174859 (2) 174860 (2) 174861
613 Air side blockoff 174685
614 Rubber Grommet - vent & drain lines
2, 11, 12
(2) 172528, Kennard #825
615 Rubber Grommet - feed & return lines (2) 172529, Kennard #2500
616 Collection Box Assembly (drain)
2, 3, 11,
12, 13,
14
173568 173569 173570 173571 173572 173573
617 Rubber Grommet (drain) 39852, Kennard #1625 - 1-1/14"
618 Drain Pan (2) 172316 (2) 173528 (2) 173529 (2) 173530 (2) 173531 (2) 173532
619 Door Latch Replacement Kit 112974