Installation Manual

11.0 Maintenance
and Service
FIGURE 9 - Electrode
Assembly (Direct
Spark)
Electrode
Burner
Proper installation
results in 0.219 ± 0.032”
(5.6mm) clearance
from ceramic tile surface
to the sparking tips of
the electrode.
5HIHUWRWKHLOOXVWUDWLRQVEHORZ
 ),*85( illustrates general arrangement of heater operation.
 ),*85(VKRZVWKHGLUHFWVSDUNDVVHPEO\
 ),*85(LOOXVWUDWHVEXUQHUUHPRYDO
$QQXDOPDLQWHQDQFH should be performed as follows:
CAUTION: Always wear protective goggles when cleaning heaters.
1.'LVFRQQHFWDOOSRZHUVRXUFHVUHODWHGWRWKHLQVWDOODWLRQDQGFORVHWKHJDVVXSSO\
YDOYHDWWKHKHDWHU
2.:LWKDQDLUKRVHRI36,N3DRUOHVVEORZRIIDOODFFXPXODWHGGXVWDQGGLUW
%ORZDLURYHUWKHFHUDPLFWLOHDYRLGLQJJDVNHWPDWHULDOEHWZHHQWLOHDQG
DOWHUQDWHO\LQWRWKHYHQWXULVHYHUDOWLPHVLQVXFFHVVLRQ%HFDUHIXOQRWWRGDPDJH
JDVNHWPDWHULDOEHWZHHQFHUDPLFWLOHV'DPDJLQJWKHPDWHULDOEHWZHHQWKHWLOHV
FRXOGOHDGWREXUQHUÀDVKEDFN
E
D
C
B
A
G
F
LEGEND
Symbol Item Description
A Gas manifold
B Gas orifice
C Venturi
D Optional heat deflector
E Heater flue exhaust path
F Ceramic tile surface
G Standard reflector assembly
FIGURE 8 - General Arrangement
1
2
Screw
Ceramic Tile
Burner Assembly
(removed)
FIGURE 10 - Burner
Replacement
Burner Removal
Instructions
1)5HPRYHVFUHZDQGVOLGH
EXUQHUEDFNZDUG
2) Pull burner up and
outward.
5HYHUVHWKHSURFHGXUHWR
UHLQVWDOOEXUQHU
11.1 Maintenance
Procedures and
Illustrations
P/N 131793R11, Page 17