Submittal

Page 16
Page __________ of __________
Limited Warranty
Model RIH/RIHV Heaters
Thomas & Betts warrants to the original owner-user that this Reznor product will be free from defects in material or workmanship.
This warranty is limited to twelve (12) months from the date of original installation, whether or not actual use begins on that date, or
eighteen (18) months from date of shipment by Reznor, whichever occurs first.
Limitations and Exclusions
Thomas & Betts Corporation’s obligations under this warranty and the sole remedy for its breach are limited to repair, at its
manufacturing facility, of any part or parts of its Reznor products which prove to be defective; or, in its sole discretion, replacement of
such products. All returns of defective parts or products must include the product model number and serial number, and must be made
through an authorized Reznor distributor or arranged through Reznor Customer Service. Authorized returns must be shipped prepaid.
Repaired or replacement parts will be shipped by Thomas & Betts F.O.B. shipping point.
1. The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal,
installation, service or handling of parts or complete products.
2. All claims under the warranty provided herein must be made within ninety (90) days from the date of discovery of the defect. Failure
to notify Thomas & Betts of a warranted defect within ninety (90) days of its discovery voids Thomas & Betts’s obligations
hereunder.
3. The warranty provided herein shall be void and of no effect in the event that (a) the product has been operated outside its designed
output capacity (heating, cooling, airflow); (b) the product has been subjected to misuse, neglect, accident, improper or inadequate
maintenance, corrosive environments, environments containing airborne contaminants (silicone, aluminum oxide, etc.), or excessive
thermal shock; (c) unauthorized modifications are made to the product; (d) the product is not installed or operated in compliance with
the manufacturers printed instructions; (e) the product is not installed and operated in compliance with applicable building, mechani-
cal, plumbing and electrical codes; or (f) the serial number of the product has been altered, defaced or removed.
4. The warranty provided herein is for repair or replacement only. Thomas & Betts Corporation shall not be liable for any loss, cost,
damage, or expense of any kind arising out of a breach of the warranty. Further, Thomas & Betts Corporation shall not be liable for any
incidental, consequential, exemplary, special, or punitive damages, nor for any loss of revenue, profit or use, arising out of a breach of
this warranty or in connection with the sale, maintenance, use, operation or repair of any Reznor product. In no event will Thomas &
Betts be liable for any amount greater than the purchase price of a defective product. The disclaimers of liability included in this
paragraph 4 shall remain in effect and shall continue to be enforceable in the event that any remedy herein shall fail of its essential
purpose.
5. THIS WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY FOR REZNOR PRODUCTS, AND IS IN LIEU OF ALL OTHER
EXPRESS AND IMPLIED WARRANTIES. THOMAS & BETTS CORPORATION SPECIFICALLY DISCLAIMS ALL OTHER EX-
PRESS AND IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, ALL IMPLIED WARRANTIES OF MERCHANTABIL-
ITY AND FITNESS FOR A PARTICULAR PURPOSE. No person or entity is authorized to bind Thomas & Betts Corporation to any
other warranty, obligation or liability for any Reznor product. Installation, operation or use of the Reznor product for which this
warranty is issued shall constitute acceptance of the terms hereof.
®
Sample Specifications
Models RIH/RIHV - High Intensity Infrared Heaters
Provide gas-fired, high-intensity infrared heaters manufactured as Reznor brand units. The heaters shall be equipped for use with
natural (propane) gas to operate on a 115 volt supply voltage [25 volt supply voltage].
The burner control system shall have a direct spark ignition with 100% safety shut-off and a solenoid gas valve with 1/2” NPT inlet.
Heater shall have single-stage [two-stage] heating.
Heaters shall be of compact modular design and rugged construction consisting of the controls; a seamless aluminized steel plenum
chamber with stainless steel ceramic tile retainer clips; surface combustion ceramic burner capable of full intensity temperature in less than
30 seconds; venturi mixer of spun metal construction for precision metering of air/gas mixture; highly polished aluminum reflector; and
balanced suspension holes.
The burner assembly shall be removable with a single screw for cleaning or replacement. The ceramic combustion surface shall reach
temperatures up to 1850°F and be of a cordierite-based grooved design with alternating rows of precision perforations producing a shorter
stable flame.
These units must be approved for installation in The United States and Canada by the Canadian Standards Association (CSA).
(Capacities, dimensions, and additional field-installed options as described in this catalog.)