Brochure
WARNING:Gas-redappliancesarenotdesignedforuseinhazardous
atmospheres containing ammable vapors or combustible dust, or
atmospherescontainingchlorinatedorhalogenatedhydrocarbons.
Installationsinpublicgaragesorairplanehangarsarepermittedwhenin
accordancewithANSI Z223.1and NFPA54Codes or CAN1-B149Codes
andenforcingauthorities.
Reznor
®
Series 100, Model F gas-red, gravity-vented unit heaters are designed for 80% thermal efciency
and are designed for use with natural or propane gas, as specied, in sizes from 25,000 to 400,000 BTUH gas
input.
Model F unit heaters are designed for ceiling suspension with a propeller fan for air delivery.
A terminal strip connector facilitates eld connection to a remote 24-volt thermostat for automatic operation.
Each unit is provided with a fan control and all required limit safety controls, including an energy cutoff (ECO)
device and a blocked vent switch.
These units are approved for installation in The United States and Canada by the Canadian Standards As-
sociation (CSA).
NOTE: When installing gravity vented appliances check local and state codes for requirements. Some states require the addition of spark
pilot Option AH2 or AH3.
● Orices for natural gas
● Aluminized steel heat exchanger
● Aluminized steel burner rack with stainless steel insert
● Spark ignited, intermittent safety pilot with electronic ame supervision
● Single-stage combination gas valve (eld adjustable for high altitude operation)
● 115/1/60 supply voltage
● 115 volt fan motor with internal overload protection
● Fan and limit safety controls
● Energy cutoff (ECO) device
● Blocked vent shutoff system
● 24-volt control voltage transformer
● Individually adjustable horizontal louvers
● Full safety fan guard
● Terminal strip connector for 24-volt eld wiring
● Convenient bottom burner access
● 2-point 3/8"-16 threaded hanger connections
● Horizontal/vertical vent outlet
● Equipped for propane gas
● E-3 (409) stainless steel heat exchanger and burner
● Two-stage gas control (50% low re) - Sizes 75-400
● Spark ignited, intermittent safety pilot with electronic ame supervision with timed lockout (timed lockout is
required for propane gas)
● Manual summer/winter switch
● Burner air shutters
● 208/230 single phase supply voltage
● 220/240 volt/50 Hertz electrical operation
● Totally enclosed 115V motor
● Low ambient fan control relay
● Power venter
● Vertical louvers
● Downturn air nozzle, 25-65°
or 50-90° variable air deector range (includes 4-point suspension kit)
● Thermostat and relay kits
● Air recirculation kits
● Manual summer/winter switch
● Multiple heater control
● 4-point suspension kit
● Unit-mounted thermostat bracket
● Step down transformer 230/115 or 460/115
● Burner air shutters
● Low ambient fan control relay kit
● Hanger kit to suspend from 1" pipe (2 or 4 point suspension)
● Single-stage and two-stage thermostats
● Thermostat guard with locking cover
● Manual shutoff valve and union
● Gas conversion kit
NOTE: Not certied for residential use.
DESCRIPTION
STANDARD FEATURES
OPTIONAL FEATURES -
FACTORY INSTALLED
OPTIONAL FEATURES -
FIELD INSTALLED
NOTE: Regulated combination redundant gas valve consists of combination pilot solenoid valve, electric gas valve, pilot lter, pressure regulator, pilot shutoff, and manual shutoff, all in
one body. Gas supply pressure must not exceed 0.5 psi (8 oz. or 14" w.c.). Minimum inlet pressure for natural gas is 5" w.c.; minimum inlet pressure for propane gas is 11" w.c.
ANSI Z83.8
CAN/CGA 2.6
MODEL F
Gas-Fires,Gravity-Vented,
Fan-TypeUnitHeaterfor
Commercial/IndustrialUse
The Energy Policy Act of 2005
mandatedthatbeginningAugust
of 2008, no Gravity Vented Unit
Heaters may be sold without an
Intermittent Ignition Device (No
Standing Pilot- Spark Ignition
Only)AND, (either an automatic
shutoff vent damper or a power
vent exhaust). Your state may
havealreadyenactedthisrestric-
tion in their local codes. Please
take note of this when placing
ordersforgravityventedunits.