INSTALLATION INSTRUCTIONS
General
Every penetration of a floor or ceiling should be
sealed.
Failure to install and properly vent the water
heater to the outdoors as outlined on pages 33
through 43 can result in unsafe operation.
Long hot water lines should be insulated to
conserve water and energy.
The water heater and water lines should
be protected from exposure to freezing
temperatures.
12" min.
(300 mm)
12" min.
(300 mm)
1/2" min.
(13 mm)
12" min.
(300 mm)
0"
(0 mm)
0" min.
(0 mm)
Sealed
Do not install the water heater
outdoors or in bathrooms,
bedrooms, or any occupied rooms
normally kept closed.
Do not install the water heater
where it is subject to vibrations.
Do not install the water heater in a
recreational vehicle, mobile home,
boat, or other watercraft.
Do not install the water heater
near vents for heating and cooling.
If necessary, maintain a minimum
clearance of 4 ft. (1.2 m).
Minimum water heater clearances from
combustible and noncombustible construction
are as follows:
1/2 in. (1.3 cm) for sides
0 in. (0 cm) for rear with support bracket(s)
12 in. (30 cm) from the bottom, top, and front