Specification

06/17 WP FORM NO. RR102CE-1 Rev. 22
4
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100
Roswell, Georgia 30076 • www.rheem.com
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario L6Y 0P5 • www.rheem.com
Water
INTEGRATED HOME COMFORT
Commercial Electric
Heavy Duty Water Heaters
I N TEGR ATED AIR & WATER
INTEGRATED HOME COMFORT
Recommended Specifications
(for trade reference only)
Water heater(s) shall be model ________________,
manufactured by Rheem, having electrical input of
__________ kW and a recovery rate of _____________ GPH
at a 100°F temperature rise. Water heater(s) shall have a
storage capacity of ___________ gallons. Water heater(s)
shall have the UL seal of certification and be factory equipped
with an CSA/ASME rated temperature and pressure relief
valve. Tank(s) shall have a double coating of high temperature
porcelain enamel and furnished with magnesium anode rods
rigidly supported. Water heater(s) shall meet or exceed the
standby loss requirements of ASHRAE. Tank(s) shall have
a working pressure of 150 psi, and shall be completely
assembled. Water heater(s) shall be approved-listed and
constructed in accordance with UL Sanitation (NSF5). Water
heater(s) shall be equipped with stainless steel “screw-in”
type elements. Tank shall be insulated with thick polyurethane
foam insulation. Water heater(s) shall be constructed with
a System Sentinel element diagnostic panel utilizing light
emitting diodes. Each LED will correspond to the number
and location of the heating elements and monitor their on-off
function. Water heater(s) shall be provided with internal power
circuit fusing, control circuit fusing, magnetic contactors,
120 volt control circuit transformer and surface mounted
thermostat or immersion thermostat(s) with manual reset high
limit control. 1-1/2" inlet and outlet water connections for 80
through 120 gallon models and 2-1/2" for 175 gallon units
shall be provided. Water heater(s) shall be covered by a three
year limited warranty against tank leaks.
When ordering ASME construction,
place (A) after the model number
(for trade reference only)
Water heater(s) shall be constructed in accordance with the
requirements of the ASME Boiler and Pressure Vessel Code,
Section IV Part HLW.
DIMENSIONAL INFORMATION
All dimensions shown in English and Metric
MODEL
APPROX. SHIPPING
WEIGHT (LBS.)
NUMBER UNITS A B C D E STD. ASME
E(S)50(A) inches 43-5/8 26-1/4 36-1/4 32 19 270 lbs. 320 lbs.
mm 1108 667 920 813 483 122 kgs. 145 kgs.
E(S)85(A) inches 57-11/16 28-1/4 49-1/2 34 20 350 lbs. 380 lbs.
mm
1765 832 826
565
318 kgs.1842
718 1258 864 508 159 kgs. 172 kgs.
E(S)120(A) inches 67-5/8 30-1/4 58-3/4 36 21 430 lbs. 460 lbs.
mm 1718
1465
768 1493 914 533 185 kgs. 209 kgs.
E175A inches 69-1/2 32-1/4 72-1/2 38-1/2 22-1/4
700 lbs.
mm
A
D
E
46-1/4"
(1175mm)
2-1/2" COLD INLET
NIPPLE
2-1/2" HOT OULET
NIPPLE
AUTOMATIC
TEMPERATURE
CONTROL
(IMMERSION ONLY)
T&P
SYSTEM SENTINEL
B
B
D
E
C C
A
4-3/4"
(121mm)
4-3/4"
(121mm)
36-1/8"
(917mm)
T&P
5"
( 127mm)
5-7/8"
( 149mm)
SYSTEM SENTINEL
AUTOMATIC
TEMPERATURE
CONTROL
(IMMERSION ONLY)
1-1/2"
COLD INLET
NIPPLE
1-1/2"
HOT OUTLET
NIPPLE
C
175 Gallon Model50, 85 and 120 Gallon Models