Specification Sheet
12
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC RCFL-H*3621
RGLR-07?AMK?
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 16 12
925 [437] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGLR-07?BRQ?
1 19500 [5.7] 9100 [2.7]
35200 [10.3] 16 12.5
900 [425] 69
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RGLR-10?BRM?
1 19500 [5.7] 9100 [2.7]
35200 [10.3] 16 12.5
925 [437] 69
2 24300 [7.1] 10900 [3.2] 1200 [566] 72
RGPE-05?BMK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 11.5
900 [425] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGPE-07?AMK?
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 15.5 12
900 [425] 69
2 24200 [7.1] 10800 [3.2] 1225 [578] 72
RGPE-07?BRQ?
1 19500 [5.7] 9100 [2.7]
35400 [10.4] 16 12.5
900 [425] 69
2 24600 [7.2] 10800 [3.2] 1225 [578] 72
RGPE-10?BRM?
1 19500 [5.7] 9100 [2.7]
35400 [10.4] 16 12.5
900 [425] 69
2 24600 [7.2] 10800 [3.2] 1225 [578] 72
RGPR-05?BMK?
1 19300 [5.7] 9100 [2.7]
34600 [10.1] 15 11.5
900 [425] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGPR-07?AMK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 12
900 [425] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGPR-07?BRQ?
1 19200 [5.6] 9200 [2.7]
35200 [10.3] 16 12.5
875 [413] 69
2 24300 [7.1] 10900 [3.2] 1200 [566] 72
RGPR-10?BRM?
1 19500 [5.7] 9100 [2.7]
35200 [10.3] 16 12
925 [437] 69
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RGRM-04?MAE?
1 19100 [5.6] 9100 [2.7]
34600 [10.1] 15 11.5
925 [437] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGRM-06?MAE?
1 18300 [5.4] 9500 [2.8]
34000 [10.0] 15.5 12
775 [366] 69
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
RGRM-07?MAE?
1 18400 [5.4] 9400 [2.8]
33800 [9.9] 15.5 11.5
800 [378] 69
2 22200 [6.5] 11600 [3.4] 1025 [484] 72
RGRM-07?YBG?
1 18700 [5.5] 9300 [2.7]
34400 [10.1] 15 11
850 [401] 69
2 23500 [6.9] 10900 [3.2] 1200 [566] 72
RGRM-09?ZAJ?
1 19300 [5.7] 9100 [2.7]
35000 [10.3] 15.5 12
950 [448] 69
2 24200 [7.1] 10800 [3.2] 1225 [578] 72
RGRM-10?ZAJ?
1 19000 [5.6] 9200 [2.7]
34600 [10.1] 15.5 12
875 [413] 69
2 23400 [6.9] 11200 [3.3] 1150 [543] 72
RGTM-06?MAE?
1 19300 [5.7] 9100 [2.7]
34200 [10.0] 15.5 12
900 [425] 69
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGTM-07?RBG?
1 18600 [5.4] 9400 [2.8]
34600 [10.1] 16 12.5
800 [378] 69
2 23100 [6.8] 11500 [3.4] 1050 [495] 72
RGTM-09?ZAJ?
1 19900 [5.8] 8900 [2.6]
35200 [10.3] 16 12
975 [460] 69
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
ROCA-070E03
1 18600 [5.4] 9400 [2.8]
34200 [10.0] 16 12.5
800 [378] 69
2 22500 [6.6] 11700 [3.4] 1000 [472] 72
ROCA-070E04
1 18600 [5.4] 9400 [2.8]
34200 [10.0] 16 12.5
800 [378] 69
2 22500 [6.6] 11700 [3.4] 1000 [472] 72
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series