Specification Sheet

13
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC
RCFL-H*3621
ROLA-070E03
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 16 12
900 [425] 69
2 24000 [7.0] 11000 [3.2] 1175 [554] 72
ROLA-070E04
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 16 12
900 [425] 69
2 24000 [7.0] 11000 [3.2] 1175 [554] 72
ROLA-115E05
1 19500 [5.7] 9100 [2.7]
35200 [10.3] 16 12.5
900 [425] 69
2 24300 [7.1] 10900 [3.2] 1200 [566] 72
RCFL-H*3621+RXMD-C06 Coil Only
1 18900 [5.5] 9100 [2.7]
34400 [10.1] 14 11.5
925 [437] 69
2 23200 [6.8] 11200 [3.3] 1125 [531] 72
RCFL-H*3821
RGFE-06?MCK?
1 18900 [5.5] 9700 [2.8]
35400 [10.4] 15.5 12
875 [413] 69
2 24200 [7.1] 11200 [3.3] 1200 [566] 72
RGFE-07?MCK?
1 18900 [5.5] 9700 [2.8]
35400 [10.4] 15.5 11.5
875 [413] 69
2 24300 [7.1] 11100 [3.3] 1225 [578] 72
RGFE-09?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGFE-10?ZCM?
1 19700 [5.8] 9500 [2.8]
35800 [10.5] 16.5 12.5
900 [425] 69
2 24700 [7.2] 11100 [3.3] 1225 [578] 72
RGFG-06?MCK?
1 18900 [5.5] 9700 [2.8]
35400 [10.4] 15.5 12
875 [413] 69
2 24200 [7.1] 11200 [3.3] 1200 [566] 72
RGFG-07?MCK?
1 18500 [5.4] 9900 [2.9]
34800 [10.2] 16 12.5
800 [378] 69
2 22800 [6.7] 12000 [3.5] 1000 [472] 72
RGFG-09?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGFG-10?ZCM?
1 19500 [5.7] 9500 [2.8]
35800 [10.5] 16 12.5
900 [425] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGGE-06?MCK?
1 19500 [5.7] 9500 [2.8]
35600 [10.4] 16 12
925 [437] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
RGGE-07?MCK?
1 18900 [5.5] 9700 [2.8]
35400 [10.4] 15.5 12
875 [413] 69
2 24200 [7.1] 11200 [3.3] 1200 [566] 72
RGGE-09?ZCM?
1 20200 [5.9] 9200 [2.7]
36000 [10.5] 16 12.5
1025 [484] 69
2 25000 [7.3] 11000 [3.2] 1250 [590] 72
RGGE-10?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGJF-06?MCK?
1 19500 [5.7] 9500 [2.8]
35600 [10.4] 16 12
925 [437] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
RGJF-07?MCK?
1 18900 [5.5] 9700 [2.8]
35400 [10.4] 15.5 12
875 [413] 69
2 24200 [7.1] 11200 [3.3] 1200 [566] 72
RGJF-09?ZCM?
1 20200 [5.9] 9200 [2.7]
36000 [10.5] 16 12.5
1025 [484] 69
2 25000 [7.3] 11000 [3.2] 1250 [590] 72
RGJF-10?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGLE-07?AMK?
1 19100 [5.6] 9700 [2.8]
35600 [10.4] 16 12.5
875 [413] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
RGLE-07?BRQ?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
925 [437] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series