Specification Sheet
16
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC
RCFL-H*3824
RGLR-12?ARM?
1 20300 [5.9] 9300 [2.7]
36200 [10.6] 16.5 13
1000 [472] 69
2 25100 [7.4] 11100 [3.3] 1225 [578] 72
RGPE-07?BRQ?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
900 [425] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGPE-10?BRM?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
900 [425] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGPE-12?ARM?
1 19100 [5.6] 9700 [2.8]
36000 [10.5] 16.5 13
875 [413] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
RGPR-07?BRQ?
1 19300 [5.7] 9700 [2.8]
36000 [10.5] 16.5 13
875 [413] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
RGPR-10?BRM?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 12.5
925 [437] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGPR-12?ARM?
1 20100 [5.9] 9300 [2.7]
36200 [10.6] 16.5 13
1000 [472] 69
2 25200 [7.4] 11000 [3.2] 1250 [590] 72
RGRM-07?YBG?
1 18900 [5.5] 9700 [2.8]
35200 [10.3] 15.5 11.5
850 [401] 69
2 24000 [7.0] 11200 [3.3] 1200 [566] 72
RGRM-09?ZAJ?
1 19500 [5.7] 9500 [2.8]
35800 [10.5] 15.5 12
950 [448] 69
2 24700 [7.2] 11100 [3.3] 1225 [578] 72
RGRM-10?ZAJ?
1 19100 [5.6] 9700 [2.8]
35200 [10.3] 16 12.5
875 [413] 69
2 23700 [6.9] 11500 [3.4] 1150 [543] 72
RGRM-12?RAJ?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16 12.5
925 [437] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGTM-07?RBG?
1 19500 [5.7] 9500 [2.8]
36200 [10.6] 16 12.5
950 [448] 69
2 25300 [7.4] 10900 [3.2] 1275 [602] 72
RGTM-09?ZAJ?
1 20000 [5.9] 9400 [2.8]
36000 [10.5] 16 12.5
975 [460] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGTM-10?RBJ?
1 20000 [5.9] 9400 [2.8]
36000 [10.5] 16.5 13
975 [460] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
ROCA-070E03
1 20100 [5.9] 9300 [2.7]
35600 [10.4] 16 12.5
1000 [472] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
ROCA-070E04
1 20100 [5.9] 9300 [2.7]
35600 [10.4] 16 12.5
1000 [472] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
ROLA-070E03
1 19700 [5.8] 9500 [2.8]
35800 [10.5] 16.5 12.5
900 [425] 69
2 24500 [7.2] 11300 [3.3] 1175 [554] 72
ROLA-070E04
1 19700 [5.8] 9500 [2.8]
35800 [10.5] 16.5 12.5
900 [425] 69
2 24500 [7.2] 11300 [3.3] 1175 [554] 72
ROLA-115E05
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
900 [425] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
RCFL-H*3824+RXMD-C06 Coil Only
1 18900 [5.5] 9500 [2.8]
35000 [10.3] 14 11.5
925 [437] 69
2 23500 [6.9] 11500 [3.4] 1125 [531] 72
RCFN-H*3624
RGFE-06?MCK?
1 21500 [6.3] 8700 [2.5]
38000 [11.1] 16.5 12.5
875 [413] 69
2 27800 [8.1] 10200 [3.0] 1200 [566] 72
RGFE-07?MCK?
1 21500 [6.3] 8700 [2.5]
38000 [11.1] 16.5 12.5
875 [413] 69
2 27900 [8.2] 10100 [3.0] 1225 [578] 72
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series