Specification Sheet

19
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC
RCFN-H*3624
RGTM-07?RBG?
1 22100 [6.5] 8500 [2.5]
39000 [11.4] 17.5 13
950 [448] 69
2 29200 [8.6] 9800 [2.9] 1275 [602] 72
RGTM-09?ZAJ?
1 22700 [6.7] 8300 [2.4]
38500 [11.3] 17.5 13
975 [460] 69
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
RGTM-10?RBJ?
1 22700 [6.7] 8300 [2.4]
38500 [11.3] 17.5 13
975 [460] 69
2 28400 [8.3] 10100 [3.0] 1225 [578] 72
ROCA-070E03
1 22800 [6.7] 8200 [2.4]
38500 [11.3] 17 13
1000 [472] 69
2 28300 [8.3] 10200 [3.0] 1200 [566] 72
ROCA-070E04
1 22800 [6.7] 8200 [2.4]
38500 [11.3] 17 13
1000 [472] 69
2 28300 [8.3] 10200 [3.0] 1200 [566] 72
ROLA-070E03
1 22300 [6.5] 8500 [2.5]
38500 [11.3] 17.5 13
900 [425] 69
2 28200 [8.3] 10300 [3.0] 1175 [554] 72
ROLA-070E04
1 22300 [6.5] 8500 [2.5]
38500 [11.3] 17.5 13
900 [425] 69
2 28200 [8.3] 10300 [3.0] 1175 [554] 72
ROLA-115E05
1 22300 [6.5] 8500 [2.5]
38500 [11.3] 17.5 13
900 [425] 69
2 28300 [8.3] 10200 [3.0] 1200 [566] 72
RCFN-H*3624+RXMD-C06 Coil Only
1 21500 [6.3] 8500 [2.5]
37600 [11.0] 15 12.5
925 [437] 69
2 27000 [7.9] 10600 [3.1] 1125 [531] 72
RCQD-3621
RGFE-06?MCK?
1 21100 [6.2] 8500 [2.5]
37200 [10.9] 16.5 12.5
875 [413] 69
2 27200 [8.0] 10000 [2.9] 1200 [566] 72
RGFE-07?MCK?
1 18200 [5.3] 9600 [2.8]
36600 [10.7] 17 13
500 [236] 69
2 25800 [7.6] 10800 [3.2] 1025 [484] 72
RGFE-09?ZCM?
1 21100 [6.2] 8500 [2.5]
37600 [11.0] 17 13
875 [413] 69
2 27600 [8.1] 10000 [2.9] 1200 [566] 72
RGFE-10?ZCM?
1 21600 [6.3] 8400 [2.5]
37600 [11.0] 17 13
900 [425] 69
2 27700 [8.1] 9900 [2.9] 1225 [578] 72
RGFG-06?MCK?
1 21100 [6.2] 8500 [2.5]
37200 [10.9] 16.5 12.5
875 [413] 69
2 27200 [8.0] 10000 [2.9] 1200 [566] 72
RGFG-07?MCK?
1 21900 [6.4] 8100 [2.4]
37200 [10.9] 16 12.5
1000 [472] 69
2 27300 [8.0] 9900 [2.9] 1225 [578] 72
RGFG-09?ZCM?
1 21100 [6.2] 8500 [2.5]
37600 [11.0] 17 13
875 [413] 69
2 27600 [8.1] 10000 [2.9] 1200 [566] 72
RGFG-10?ZCM?
1 21600 [6.3] 8400 [2.5]
37600 [11.0] 17 13
900 [425] 69
2 27600 [8.1] 10000 [2.9] 1200 [566] 72
RGJF-06?MCK?
1 17900 [5.2] 9700 [2.8]
36800 [10.8] 17 13
475 [224] 69
2 26000 [7.6] 10800 [3.2] 1025 [484] 72
RGJF-07?MCK?
1 17900 [5.2] 9700 [2.8]
36800 [10.8] 17 13
475 [224] 69
2 26000 [7.6] 10800 [3.2] 1025 [484] 72
RGJF-09?ZCM?
1 22400 [6.6] 8000 [2.3]
37800 [11.1] 17 13
1025 [484] 69
2 28000 [8.2] 9800 [2.9] 1250 [590] 72
RGJF-10?ZCM?
1 21100 [6.2] 8500 [2.5]
37600 [11.0] 17 13
875 [413] 69
2 27600 [8.1] 10000 [2.9] 1200 [566] 72
RGPE-05?BMK?
1 21400 [6.3] 8400 [2.5]
37400 [11.0] 17 12.5
900 [425] 69
2 27400 [8.0] 10000 [2.9] 1200 [566] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series