Specification Sheet
20
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC
RCQD-3621
RGPE-07?AMK?
1 21600 [6.3] 8400 [2.5]
37600 [11.0] 17 13
900 [425] 69
2 27700 [8.1] 9900 [2.9] 1225 [578] 72
RGPE-07?BRQ?
1 20000 [5.9] 9000 [2.6]
37000 [10.8] 17.5 13
725 [342] 69
2 26200 [7.7] 10800 [3.2] 1025 [484] 72
RGPE-10?BRM?
1 21600 [6.3] 8400 [2.5]
38000 [11.1] 17.5 13
900 [425] 69
2 28100 [8.2] 9900 [2.9] 1225 [578] 72
RGPR-05?BMK?
1 21400 [6.3] 8400 [2.5]
37200 [10.9] 16 12.5
900 [425] 69
2 27200 [8.0] 10000 [2.9] 1200 [566] 72
RGPR-07?AMK?
1 21600 [6.3] 8400 [2.5]
37400 [11.0] 17 13
900 [425] 69
2 27400 [8.0] 10000 [2.9] 1200 [566] 72
RGPR-07?BRQ?
1 21300 [6.2] 8500 [2.5]
37800 [11.1] 17.5 13
875 [413] 69
2 27800 [8.1] 10000 [2.9] 1200 [566] 72
RGPR-10?BRM?
1 21600 [6.3] 8400 [2.5]
37800 [11.1] 17 13
925 [437] 69
2 27900 [8.2] 9900 [2.9] 1225 [578] 72
RGRM-04?MAE?
1 20100 [5.9] 8900 [2.6]
36600 [10.7] 17 12.5
750 [354] 69
2 25800 [7.6] 10800 [3.2] 1025 [484] 72
RGRM-06?MAE?
1 21400 [6.3] 8400 [2.5]
37000 [10.8] 16.5 12
900 [425] 69
2 26900 [7.9] 10100 [3.0] 1175 [554] 72
RGRM-07?MAE?
1 20400 [6.0] 8800 [2.6]
36400 [10.7] 16.5 12.5
800 [378] 69
2 25600 [7.5] 10800 [3.2] 1025 [484] 72
RGRM-07?YBG?
1 20800 [6.1] 8600 [2.5]
37000 [10.8] 16.5 12
850 [401] 69
2 27000 [7.9] 10000 [2.9] 1200 [566] 72
RGRM-09?ZAJ?
1 21400 [6.3] 8400 [2.5]
37600 [11.0] 16.5 13
950 [448] 69
2 27700 [8.1] 9900 [2.9] 1225 [578] 72
RGRM-10?ZAJ?
1 21100 [6.2] 8500 [2.5]
37200 [10.9] 17 13
875 [413] 69
2 26800 [7.9] 10400 [3.0] 1150 [543] 72
RGTM-06?MAE?
1 21400 [6.3] 8400 [2.5]
36600 [10.7] 17 13
900 [425] 69
2 25800 [7.6] 10800 [3.2] 1025 [484] 72
RGTM-07?RBG?
1 21600 [6.3] 8400 [2.5]
38000 [11.1] 17 13
950 [448] 69
2 28300 [8.3] 9700 [2.8] 1275 [602] 72
RGTM-09?ZAJ?
1 22000 [6.4] 8200 [2.4]
37800 [11.1] 17 13
975 [460] 69
2 27900 [8.2] 9900 [2.9] 1225 [578] 72
ROCA-070E03
1 22100 [6.5] 8100 [2.4]
37600 [11.0] 16.5 13
1000 [472] 69
2 27600 [8.1] 10000 [2.9] 1200 [566] 72
ROCA-070E04
1 22100 [6.5] 8100 [2.4]
37600 [11.0] 16.5 13
1000 [472] 69
2 27600 [8.1] 10000 [2.9] 1200 [566] 72
ROLA-070E03
1 21600 [6.3] 8400 [2.5]
37600 [11.0] 17 13
900 [425] 69
2 27500 [8.1] 10100 [3.0] 1175 [554] 72
ROLA-070E04
1 21600 [6.3] 8400 [2.5]
37600 [11.0] 17 13
900 [425] 69
2 27500 [8.1] 10100 [3.0] 1175 [554] 72
ROLA-115E05
1 21600 [6.3] 8400 [2.5]
37800 [11.1] 17 13
900 [425] 69
2 27800 [8.1] 10000 [2.9] 1200 [566] 72
RCQD-3621+RXMD-C06 Coil Only
1 20800 [6.1] 8400 [2.5]
36800 [10.8] 14.5 12
925 [437] 69
2 26400 [7.7] 10400 [3.0] 1125 [531] 72
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series