Specification Sheet
22
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC
RCQD-3624
RGTM-09?ZAJ?
1 22500 [6.6] 8500 [2.5]
37600 [11.0] 17 13
975 [460] 69
2 27900 [8.2] 9700 [2.8] 1225 [578] 72
RGTM-10?RBJ?
1 22500 [6.6] 8500 [2.5]
37800 [11.1] 17 13
975 [460] 69
2 28100 [8.2] 9700 [2.8] 1225 [578] 72
ROCA-070E03
1 22600 [6.6] 8400 [2.5]
37400 [11.0] 16.5 13
1000 [472] 69
2 27500 [8.1] 9900 [2.9] 1200 [566] 72
ROCA-070E04
1 22600 [6.6] 8400 [2.5]
37400 [11.0] 16.5 13
1000 [472] 69
2 27500 [8.1] 9900 [2.9] 1200 [566] 72
ROLA-070E03
1 21900 [6.4] 8700 [2.5]
37400 [11.0] 17 13
900 [425] 69
2 27400 [8.0] 10000 [2.9] 1175 [554] 72
ROLA-070E04
1 21900 [6.4] 8700 [2.5]
37400 [11.0] 17 13
900 [425] 69
2 27400 [8.0] 10000 [2.9] 1175 [554] 72
ROLA-115E05
1 22100 [6.5] 8700 [2.5]
37600 [11.0] 17 13
900 [425] 69
2 27700 [8.1] 9900 [2.9] 1200 [566] 72
RCQD-3624+RXMD-C06 Coil Only
1 21300 [6.2] 8700 [2.5]
36600 [10.7] 14.5 12
925 [437] 69
2 26400 [7.7] 10200 [3.0] 1125 [531] 72
RCSL-H*3621 RHPL-HM3621
1 19500 [5.7] 9100 [2.7]
35400 [10.4] 16 12.5
925 [437] 69
2 24600 [7.2] 10800 [3.2] 1225 [578] 72
RCSL-H*3821 RHPL-HM3821
1 19700 [5.8] 9500 [2.8]
35600 [10.4] 16.5 13
950 [448] 69
2 24100 [7.1] 11500 [3.4] 1150 [543] 72
039JEC
RCSN-H*3624 ➀
RHPN-HM3624
1 17100 [5.0] 4700 [1.4]
39500 [11.6] 19.5 13.5
825 [389] 69
2 27900 [8.2] 11600 [3.4] 1175 [554] 73
1 - dehumid 16800 [4.9] 5000 [1.5] 725 [342]
2 - dehumid 25600 [7.5] 12400 [3.6] 975 [460]
RCFL-H*3617
RGFG-06?MCK?
1 14400 [4.2] 5500 [1.6]
35000 [10.3] 16.5 11.5
725 [342] 69
2 22000 [6.4] 13000 [3.8] 1000 [472] 73
RGFG-07?MCK?
1 15100 [4.4] 5300 [1.6]
34800 [10.2] 16.5 11.5
800 [378] 69
2 21750 [6.4] 13050 [3.8] 1000 [472] 73
RGGE-06?MCK?
1 15250 [4.5] 5350 [1.6]
35600 [10.4] 16 11.5
925 [437] 69
2 23450 [6.9] 12150 [3.6] 1200 [566] 73
RGJF-06?MCK?
1 15250 [4.5] 5350 [1.6]
35600 [10.4] 16 11.5
925 [437] 69
2 23450 [6.9] 12150 [3.6] 1200 [566] 73
RGJF-07?MCK?
1 15100 [4.4] 5300 [1.6]
35600 [10.4] 16 11.5
875 [413] 69
2 23450 [6.9] 12150 [3.6] 1200 [566] 73
RGLE-07?AMK?
1 15250 [4.5] 5350 [1.6]
35800 [10.5] 16.5 11.5
875 [413] 69
2 23600 [6.9] 12200 [3.6] 1200 [566] 73
RGPE-05?BMK?
1 15250 [4.5] 5350 [1.6]
35600 [10.4] 16 11.5
900 [425] 69
2 23450 [6.9] 12150 [3.6] 1200 [566] 73
RGRM-04?MAE?
1 14300 [4.2] 5500 [1.6]
35600 [10.4] 16 11.5
750 [354] 69
2 23450 [6.9] 12150 [3.6] 1025 [484] 73
RGRM-06?MAE?
1 14450 [4.2] 5550 [1.6]
35400 [10.4] 16 11.5
775 [366] 69
2 23250 [6.8] 12150 [3.6] 1000 [472] 73
RGRM-07?MAE?
1 14400 [4.2] 5500 [1.6]
35400 [10.4] 15.5 11
800 [378] 69
2 23300 [6.8] 12100 [3.5] 1025 [484] 73
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series