Specification Sheet

23
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
039JEC
RCFL-H*3617 RGTM-06?MAE?
1 15550 [4.6] 5450 [1.6]
35800 [10.5] 15 11
1075 [507] 69
2 23600 [6.9] 12200 [3.6] 1225 [578] 73
RCFL-H*3617+RXMD-C06 Coil Only
1 14100 [4.1] 5400 [1.6]
35600 [10.4] 14 11
800 [378] 69
2 23400 [6.9] 12200 [3.6] 1075 [507] 73
RCFL-H*3621
RGFG-06?MCK?
1 15300 [4.5] 5100 [1.5]
35200 [10.3] 16 11
875 [413] 69
2 23150 [6.8] 12050 [3.5] 1200 [566] 73
RGFG-07?MCK?
1 13500 [4.0] 5900 [1.7]
34800 [10.2] 16.5 11.5
550 [260] 69
2 21900 [6.4] 12900 [3.8] 1000 [472] 73
RGFG-09?ZCM?
1 15500 [4.5] 5100 [1.5]
35600 [10.4] 16.5 11.5
875 [413] 69
2 23450 [6.9] 12150 [3.6] 1200 [566] 73
RGFG-10?ZCM?
1 13850 [4.1] 5750 [1.7]
35600 [10.4] 16.5 11.5
600 [283] 69
2 23500 [6.9] 12100 [3.5] 1200 [566] 73
RGGE-06?MCK?
1 15500 [4.5] 5300 [1.6]
35800 [10.5] 16 11.5
925 [437] 69
2 23650 [6.9] 12150 [3.6] 1200 [566] 73
RGGE-09?ZCM?
1 13800 [4.0] 5800 [1.7]
36000 [10.5] 16 11.5
575 [271] 69
2 24000 [7.0] 12000 [3.5] 1225 [578] 73
RGGE-10?ZCM?
1 13800 [4.0] 5800 [1.7]
35800 [10.5] 16.5 11.5
575 [271] 69
2 23800 [7.0] 12000 [3.5] 1200 [566] 73
RGJF-06?MCK?
1 15500 [4.5] 5300 [1.6]
35800 [10.5] 16 11.5
925 [437] 69
2 23650 [6.9] 12150 [3.6] 1200 [566] 73
RGJF-07?MCK?
1 15350 [4.5] 5250 [1.5]
35800 [10.5] 16 11.5
875 [413] 69
2 23650 [6.9] 12150 [3.6] 1200 [566] 73
RGJF-09?ZCM?
1 15300 [4.5] 5300 [1.6]
36200 [10.6] 16.5 12
875 [413] 69
2 23900 [7.0] 12300 [3.6] 1225 [578] 73
RGJF-10?ZCM?
1 15300 [4.5] 5300 [1.6]
36000 [10.5] 16.5 12
875 [413] 69
2 23750 [7.0] 12250 [3.6] 1200 [566] 73
RGLE-07?AMK?
1 15300 [4.5] 5300 [1.6]
36000 [10.5] 16.5 11.5
875 [413] 69
2 23800 [7.0] 12200 [3.6] 1200 [566] 73
RGLE-07?BRQ?
1 15650 [4.6] 5350 [1.6]
36200 [10.6] 17 12
925 [437] 69
2 23850 [7.0] 12350 [3.6] 1225 [578] 73
RGLE-10?BRM?
1 15500 [4.5] 5300 [1.6]
36200 [10.6] 17.5 12.5
875 [413] 69
2 23850 [7.0] 12350 [3.6] 1200 [566] 73
RGPE-05?BMK?
1 15300 [4.5] 5300 [1.6]
35800 [10.5] 16 11.5
900 [425] 69
2 23650 [6.9] 12150 [3.6] 1200 [566] 73
RGPE-07?BRQ?
1 15450 [4.5] 5350 [1.6]
36200 [10.6] 17 12
900 [425] 69
2 23850 [7.0] 12350 [3.6] 1225 [578] 73
RGPE-10?BRM?
1 15450 [4.5] 5350 [1.6]
36200 [10.6] 17 12
900 [425] 69
2 23850 [7.0] 12350 [3.6] 1225 [578] 73
RGRM-04?MAE?
1 14150 [4.1] 5450 [1.6]
35000 [10.3] 16 11.5
750 [354] 69
2 23000 [6.7] 12000 [3.5] 1025 [484] 73
RGRM-06?MAE?
1 14250 [4.2] 5450 [1.6]
35000 [10.3] 16 11.5
775 [366] 69
2 23000 [6.7] 12000 [3.5] 1000 [472] 73
RGRM-07?MAE?
1 14250 [4.2] 5450 [1.6]
34800 [10.2] 15.5 11
800 [378] 69
2 22850 [6.7] 11950 [3.5] 1025 [484] 73
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series