Specification Sheet

24
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
039JEC
RCFL-H*3621
RGRM-07?YBG?
1 14050 [4.1] 5350 [1.6]
34800 [10.2] 16 11.5
700 [330] 69
2 22900 [6.7] 11900 [3.5] 975 [460] 73
RGRM-09?ZAJ?
1 14600 [4.3] 5600 [1.6]
35800 [10.5] 15.5 11.5
950 [448] 69
2 23550 [6.9] 12250 [3.6] 1225 [578] 73
RGRM-10?ZAJ?
1 14450 [4.2] 5550 [1.6]
35600 [10.4] 16 11.5
875 [413] 69
2 23400 [6.9] 12200 [3.6] 1150 [543] 73
RGTM-06?MAE?
1 15800 [4.6] 5400 [1.6]
35600 [10.4] 15.5 11
1075 [507] 69
2 23450 [6.9] 12150 [3.6] 1225 [578] 73
RGTM-07?RBG?
1 15650 [4.6] 5350 [1.6]
36400 [10.7] 16.5 12
950 [448] 69
2 24050 [7.0] 12350 [3.6] 1275 [602] 73
RGTM-09?ZAJ?
1 15600 [4.6] 5400 [1.6]
36200 [10.6] 16.5 12
975 [460] 69
2 23900 [7.0] 12300 [3.6] 1225 [578] 73
RCFL-H*3621+RXMD-C06 Coil Only
1 14100 [4.1] 5400 [1.6]
35600 [10.4] 14 11
875 [413] 69
2 23400 [6.9] 12200 [3.6] 1150 [543] 73
RCFL-H*3821
RGFE-06?MCK?
1 18000 [5.3] 7600 [2.2]
37000 [10.8] 16 12.5
875 [413] 69
2 25400 [7.4] 11600 [3.4] 1200 [566] 73
RGFE-07?MCK?
1 15400 [4.5] 8500 [2.5]
36600 [10.7] 17 13
500 [236] 69
2 24400 [7.1] 12200 [3.6] 1025 [484] 73
RGFE-09?ZCM?
1 18100 [5.3] 7600 [2.2]
37400 [11.0] 17 13
875 [413] 69
2 25800 [7.6] 11600 [3.4] 1200 [566] 73
RGFE-10?ZCM?
1 18300 [5.4] 7600 [2.2]
37600 [11.0] 17 13
900 [425] 69
2 26400 [7.7] 11200 [3.3] 1225 [578] 73
RGFG-06?MCK?
1 18000 [5.3] 7600 [2.2]
37000 [10.8] 16 12.5
875 [413] 69
2 25400 [7.4] 11600 [3.4] 1200 [566] 73
RGFG-07?MCK?
1 18700 [5.5] 7300 [2.1]
37200 [10.9] 15.5 12
1000 [472] 69
2 25800 [7.6] 11400 [3.3] 1225 [578] 73
RGFG-09?ZCM?
1 18100 [5.3] 7600 [2.2]
37400 [11.0] 17 13
875 [413] 69
2 25800 [7.6] 11600 [3.4] 1200 [566] 73
RGFG-10?ZCM?
1 18300 [5.4] 7600 [2.2]
37400 [11.0] 17 13
900 [425] 69
2 25800 [7.6] 11600 [3.4] 1200 [566] 73
RGGE-06?MCK?
1 15200 [4.5] 8600 [2.5]
36800 [10.8] 16.5 13
475 [224] 69
2 24600 [7.2] 12200 [3.6] 1025 [484] 73
RGGE-07?MCK?
1 17200 [5.0] 8000 [2.3]
36800 [10.8] 16.5 13
750 [354] 69
2 24400 [7.1] 12400 [3.6] 1025 [484] 73
RGGE-09?ZCM?
1 18100 [5.3] 7600 [2.2]
37800 [11.1] 17 13
875 [413] 69
2 26400 [7.7] 11400 [3.3] 1225 [578] 73
RGGE-10?ZCM?
1 18100 [5.3] 7600 [2.2]
37400 [11.0] 17 13
875 [413] 69
2 25800 [7.6] 11600 [3.4] 1200 [566] 73
RGJF-06?MCK?
1 17000 [5.0] 8000 [2.3]
36800 [10.8] 17 13
725 [342] 69
2 24600 [7.2] 12200 [3.6] 1025 [484] 73
RGJF-07?MCK?
1 18000 [5.3] 7600 [2.2]
37200 [10.9] 16 12.5
875 [413] 69
2 25600 [7.5] 11600 [3.4] 1200 [566] 73
RGJF-09?ZCM?
1 18100 [5.3] 7600 [2.2]
37800 [11.1] 17 13
875 [413] 69
2 26400 [7.7] 11400 [3.3] 1225 [578] 73
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series