Specification Sheet

27
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
039JEC
RCFL-H*3824
RGRM-12?RAJ?
1 18500 [5.4] 7500 [2.2]
37800 [11.1] 17 13
925 [437] 69
2 26400 [7.7] 11400 [3.3] 1225 [578] 73
RGTM-07?RBG?
1 18700 [5.5] 7400 [2.2]
38000 [11.1] 17 13
950 [448] 69
2 26800 [7.9] 11200 [3.3] 1275 [602] 73
RGTM-09?ZAJ?
1 18900 [5.5] 7400 [2.2]
37800 [11.1] 17 13
975 [460] 69
2 26400 [7.7] 11400 [3.3] 1225 [578] 73
RGTM-10?RBJ?
1 18900 [5.5] 7400 [2.2]
37800 [11.1] 17 13
975 [460] 69
2 26600 [7.8] 11200 [3.3] 1225 [578] 73
ROCA-070E03
1 19000 [5.6] 7300 [2.1]
37400 [11.0] 16.5 13
1000 [472] 69
2 25800 [7.6] 11600 [3.4] 1200 [566] 73
ROCA-070E04
1 19000 [5.6] 7300 [2.1]
37400 [11.0] 16.5 13
1000 [472] 69
2 25800 [7.6] 11600 [3.4] 1200 [566] 73
ROLA-070E03
1 18300 [5.4] 7600 [2.2]
37600 [11.0] 17 13
900 [425] 69
2 26000 [7.6] 11600 [3.4] 1175 [554] 73
ROLA-070E04
1 18300 [5.4] 7600 [2.2]
37600 [11.0] 17 13
900 [425] 69
2 26000 [7.6] 11600 [3.4] 1175 [554] 73
ROLA-115E05
1 18300 [5.4] 7600 [2.2]
37600 [11.0] 17 13
900 [425] 69
2 26000 [7.6] 11600 [3.4] 1200 [566] 73
RCFL-H*3824+RXMD-C06 Coil Only
1 17100 [5.0] 7800 [2.3]
37000 [10.8] 15 12
825 [389] 69
2 25400 [7.4] 11600 [3.4] 1175 [554] 73
RCFN-H*3624
RGFE-09?ZCM?
1 17100 [5.0] 4700 [1.4]
39000 [11.4] 18 13
875 [413] 69
2 27750 [8.1] 11250 [3.3] 1200 [566] 73
RGFE-10?ZCM?
1 17250 [5.1] 4750 [1.4]
39500 [11.6] 18 13
900 [425] 69
2 27850 [8.2] 11650 [3.4] 1225 [578] 73
RGFE-12?RCM?
1 17100 [5.0] 4700 [1.4]
39500 [11.6] 18.5 13
875 [413] 69
2 28000 [8.2] 11500 [3.4] 1225 [578] 73
RGFG-09?ZCM?
1 17300 [5.1] 4500 [1.3]
39000 [11.4] 18 13
875 [413] 69
2 27550 [8.1] 11450 [3.4] 1200 [566] 73
RGFG-10?ZCM?
1 15500 [4.5] 5100 [1.5]
39000 [11.4] 18 13
600 [283] 69
2 27500 [8.1] 11500 [3.4] 1200 [566] 73
RGFG-12?RCM?
1 17400 [5.1] 4600 [1.3]
39500 [11.6] 18.5 13
875 [413] 69
2 28250 [8.3] 11250 [3.3] 1225 [578] 73
RGGE-09?ZCM?
1 17300 [5.1] 4500 [1.3]
39500 [11.6] 18 13
875 [413] 69
2 28200 [8.3] 11300 [3.3] 1225 [578] 73
RGGE-10?ZCM?
1 15400 [4.5] 5300 [1.6]
39000 [11.4] 18 13
575 [271] 69
2 27600 [8.1] 11400 [3.3] 1200 [566] 73
RGJF-09?ZCM?
1 17100 [5.0] 4700 [1.4]
39500 [11.6] 18 13
875 [413] 69
2 28050 [8.2] 11450 [3.4] 1225 [578] 73
RGJF-10?ZCM?
1 17100 [5.0] 4700 [1.4]
39000 [11.4] 18 13
875 [413] 69
2 27750 [8.1] 11250 [3.3] 1200 [566] 73
RGJF-12?RCM?
1 17100 [5.0] 4700 [1.4]
39500 [11.6] 18.5 13.5
875 [413] 69
2 27850 [8.2] 11650 [3.4] 1200 [566] 73
RGLE-07?BRQ?
1 17250 [5.1] 4750 [1.4]
39500 [11.6] 18.5 13.5
925 [437] 69
2 28000 [8.2] 11500 [3.4] 1225 [578] 73
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series