Specification Sheet

29
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
039JEC RCQD-3621
RGFG-06?MCK?
1 15200 [4.5] 5200 [1.5]
37600 [11.0] 17 12
575 [271] 69
2 26550 [7.8] 11050 [3.2] 1200 [566] 73
RGFG-07?MCK?
1 15250 [4.5] 5150 [1.5]
37800 [11.1] 17 12
600 [283] 69
2 27000 [7.9] 10800 [3.2] 1225 [578] 73
RGFG-09?ZCM?
1 17200 [5.0] 4400 [1.3]
38000 [11.1] 17.5 12.5
875 [413] 69
2 26850 [7.9] 11150 [3.3] 1200 [566] 73
RGFG-10?ZCM?
1 15250 [4.5] 5150 [1.5]
38000 [11.1] 17.5 12.5
600 [283] 69
2 26850 [7.9] 11150 [3.3] 1200 [566] 73
RGJF-06?MCK?
1 17200 [5.0] 4600 [1.3]
37800 [11.1] 17 12.5
925 [437] 69
2 26650 [7.8] 11150 [3.3] 1200 [566] 73
RGJF-07?MCK?
1 16850 [4.9] 4550 [1.3]
37800 [11.1] 17 12
875 [413] 69
2 26700 [7.8] 11100 [3.3] 1200 [566] 73
RGJF-09?ZCM?
1 17000 [5.0] 4600 [1.3]
38500 [11.3] 17.5 13
875 [413] 69
2 27100 [7.9] 11300 [3.3] 1225 [578] 73
RGJF-10?ZCM?
1 17050 [5.0] 4550 [1.3]
38000 [11.1] 17.5 12.5
875 [413] 69
2 26800 [7.9] 11200 [3.3] 1200 [566] 73
RGPE-05?BMK?
1 17000 [5.0] 4600 [1.3]
37800 [11.1] 17 12.5
900 [425] 69
2 26700 [7.8] 11100 [3.3] 1200 [566] 73
RGPE-07?AMK?
1 17200 [5.0] 4600 [1.3]
38000 [11.1] 17.5 12.5
900 [425] 69
2 26950 [7.9] 11050 [3.2] 1225 [578] 73
RGPE-07?BRQ?
1 17200 [5.0] 4600 [1.3]
38500 [11.3] 18 13
900 [425] 69
2 27300 [8.0] 11200 [3.3] 1225 [578] 73
RGPE-10?BRM?
1 17200 [5.0] 4600 [1.3]
38500 [11.3] 18 13
900 [425] 69
2 27250 [8.0] 11250 [3.3] 1225 [578] 73
RGRM-04?MAE?
1 16150 [4.7] 4650 [1.4]
36800 [10.8] 16.5 12
750 [354] 69
2 26250 [7.7] 10550 [3.1] 1025 [484] 73
RGRM-06?MAE?
1 16450 [4.8] 4750 [1.4]
37400 [11.0] 16 11.5
900 [425] 69
2 26700 [7.8] 10700 [3.1] 1175 [554] 73
RGRM-07?MAE?
1 16350 [4.8] 4650 [1.4]
36800 [10.8] 16.5 12
800 [378] 69
2 26300 [7.7] 10500 [3.1] 1025 [484] 73
RGRM-07?YBG?
1 16300 [4.8] 4700 [1.4]
37200 [10.9] 16 11.5
850 [401] 69
2 26550 [7.8] 10650 [3.1] 1200 [566] 73
RGRM-09?ZAJ?
1 16800 [4.9] 4800 [1.4]
37800 [11.1] 16.5 12
950 [448] 69
2 27000 [7.9] 10800 [3.2] 1225 [578] 73
RGRM-10?ZAJ?
1 16450 [4.8] 4750 [1.4]
37600 [11.0] 16.5 12.5
875 [413] 69
2 26850 [7.9] 10750 [3.1] 1150 [543] 73
ROCA-070E03
1 17350 [5.1] 4650 [1.4]
37600 [11.0] 16 12.5
1000 [472] 69
2 26850 [7.9] 10750 [3.1] 1200 [566] 73
ROCA-070E04
1 17350 [5.1] 4650 [1.4]
37600 [11.0] 16 12.5
1000 [472] 69
2 26850 [7.9] 10750 [3.1] 1200 [566] 73
ROLA-070E03
1 17200 [5.0] 4750 [1.4]
37600 [11.0] 16.5 13
900 [425] 69
2 26950 [7.9] 10650 [3.1] 1175 [554] 73
ROLA-070E04
1 17200 [5.0] 4600 [1.3]
37600 [11.0] 16.5 13
900 [425] 69
2 26950 [7.9] 10650 [3.1] 1175 [554] 73
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series