Specification Sheet

31
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
039JEC
RCQD-3624 ROLA-115E05
1 17200 [5.0] 4600 [1.3]
37600 [11.0] 17 13
900 [425] 69
2 26950 [7.9] 10650 [3.1] 1200 [566] 73
RCQD-3624+RXMD-C06 Coil Only
1 16200 [4.7] 4600 [1.3]
37600 [11.0] 14.5 11.5
825 [389] 69
2 26200 [7.7] 11400 [3.3] 1175 [554] 73
RCSL-H*3621 RHPL-HM3621
1 14750 [4.3] 5650 [1.7]
36200 [10.6] 17 12
925 [437] 69
2 23800 [7.0] 12400 [3.6] 1225 [578] 73
048JEC
RCSN-H*4824
RHPN-HM4824
1 20800 [6.1] 5800 [1.7]
48500 [14.2] 18 13
1000 [472] 73
2 35800 [10.5] 12700 [3.7] 1600 [755] 74
1 - dehumid 19200 [5.6] 6800 [2.0] 825 [389]
2 - dehumid 32800 [9.6] 14200 [4.2] 1300 [613]
RCFL-H*4821
RGFE-07?MCK?
1 17100 [5.0] 6900 [2.0]
42500 [12.5] 15.5 11
875 [413] 73
2 28700 [8.4] 13800 [4.0] 1225 [578] 74
RGFE-09?ZCM?
1 17800 [5.2] 7200 [2.1]
43500 [12.7] 15 10.5
1200 [566] 73
2 29500 [8.6] 14100 [4.1] 1600 [755] 74
RGFE-10?ZCM?
1 17800 [5.2] 7200 [2.1]
43500 [12.7] 15 10.5
1225 [578] 73
2 29550 [8.7] 13950 [4.1] 1600 [755] 74
RGFG-07?MCK?
1 17100 [5.0] 7300 [2.1]
42500 [12.5] 15.5 11
925 [437] 73
2 26250 [7.7] 16250 [4.8] 1225 [578] 74
RGFG-09?ZCM?
1 16200 [4.7] 7800 [2.3]
43500 [12.7] 16 10.5
775 [366] 73
2 29350 [8.6] 14150 [4.1] 1600 [755] 74
RGFG-10?ZCM?
1 15850 [4.6] 7950 [2.3]
43000 [12.6] 16 11
725 [342] 73
2 27500 [8.1] 15500 [4.5] 1400 [661] 74
RGGE-09?ZCM?
1 17950 [5.3] 7250 [2.1]
43500 [12.7] 15.5 11
1225 [578] 73
2 29650 [8.7] 13850 [4.1] 1600 [755] 74
RGGE-10?ZCM?
1 17800 [5.2] 7200 [2.1]
43500 [12.7] 15 10.5
1200 [566] 73
2 29500 [8.6] 14000 [4.1] 1600 [755] 74
RGJF-09?ZCM?
1 16300 [4.8] 7900 [2.3]
44000 [12.9] 16 11
775 [366] 73
2 29200 [8.6] 14800 [4.3] 1600 [755] 74
RGJF-10?ZCM?
1 16300 [4.8] 7900 [2.3]
43500 [12.7] 16 10.5
775 [366] 73
2 29200 [8.6] 14300 [4.2] 1600 [755] 74
RGLE-07?BRQ?
1 17950 [5.3] 7250 [2.1]
44000 [12.9] 16 11
1225 [578] 73
2 29800 [8.7] 14200 [4.2] 1600 [755] 74
RGLE-10?BRM?
1 17950 [5.3] 7250 [2.1]
44500 [13.0] 16 11.5
1200 [566] 73
2 30100 [8.8] 14300 [4.2] 1600 [755] 74
RGPE-07?AMK?
1 17250 [5.1] 6950 [2.0]
42500 [12.5] 16.5 11.5
900 [425] 73
2 29000 [8.5] 13500 [4.0] 1225 [578] 74
RGPE-07?BRQ?
1 17950 [5.3] 7250 [2.1]
44000 [12.9] 16 11
1225 [578] 73
2 29750 [8.7] 14250 [4.2] 1600 [755] 74
RGPE-10?BRM?
1 18150 [5.3] 7250 [2.1]
44000 [12.9] 16 11.5
1225 [578] 73
2 29950 [8.8] 14050 [4.1] 1625 [767] 74
RGRM-07?MAE?
1 17150 [5.0] 7050 [2.1]
43000 [12.6] 15 11
950 [448] 73
2 28600 [8.4] 14400 [4.2] 1225 [578] 74
RGRM-07?YBG?
1 17450 [5.1] 7150 [2.1]
43500 [12.7] 14.5 10.5
1050 [495] 73
2 28900 [8.5] 14600 [4.3] 1400 [661] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series