Specification Sheet

33
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
048JEC
RCFL-H*4824
RGRM-09?ZAJ?
1 17950 [5.3] 6850 [2.0]
44000 [12.9] 16 12
950 [448] 73
2 29550 [8.7] 14450 [4.2] 1225 [578] 74
RGRM-10?ZAJ?
1 18100 [5.3] 6900 [2.0]
44000 [12.9] 16 11.5
1025 [484] 73
2 29800 [8.7] 14200 [4.2] 1425 [672] 74
RGRM-12?RAJ?
1 17950 [5.3] 6850 [2.0]
44000 [12.9] 16.5 12
925 [437] 73
2 29700 [8.7] 14300 [4.2] 1225 [578] 74
RGTM-09?ZAJ?
1 18400 [5.4] 7000 [2.1]
44500 [13.0] 15.5 11
1250 [590] 73
2 30250 [8.9] 14250 [4.2] 1600 [755] 74
RCFL-H*4824+RXMD-C06 Coil Only
1 19200 [5.6] 6200 [1.8]
44000 [12.9] 14 11
1075 [507] 73
2 29600 [8.7] 14400 [4.2] 1425 [672] 74
RCFN-H*4824
RGFE-09?ZCM?
1 21050 [6.2] 5950 [1.7]
47500 [13.9] 16.5 11.5
1200 [566] 73
2 35000 [10.3] 12500 [3.7] 1600 [755] 74
RGFE-10?ZCM?
1 21250 [6.2] 5950 [1.7]
47000 [13.8] 16.5 11.5
1225 [578] 73
2 34800 [10.2] 12200 [3.6] 1600 [755] 74
RGFE-12?RCM?
1 21200 [6.2] 6000 [1.8]
47500 [13.9] 17 12
1225 [578] 73
2 35150 [10.3] 12350 [3.6] 1625 [767] 74
RGFG-09?ZCM?
1 19000 [5.6] 6600 [1.9]
47500 [13.9] 17.5 11.5
775 [366] 73
2 35150 [10.3] 12350 [3.6] 1600 [755] 74
RGFG-10?ZCM?
1 19200 [5.6] 6400 [1.9]
47500 [13.9] 17.5 11.5
800 [378] 73
2 35450 [10.4] 12050 [3.5] 1650 [779] 74
RGFG-12?RCM?
1 19100 [5.6] 6500 [1.9]
47500 [13.9] 17.5 12
775 [366] 73
2 35050 [10.3] 12450 [3.6] 1625 [767] 74
RGGE-09?ZCM?
1 21200 [6.2] 6000 [1.8]
47500 [13.9] 17 12
1225 [578] 73
2 35150 [10.3] 12350 [3.6] 1600 [755] 74
RGGE-10?ZCM?
1 21050 [6.2] 5950 [1.7]
47500 [13.9] 16.5 11.5
1200 [566] 73
2 34950 [10.2] 12550 [3.7] 1600 [755] 74
RGGE-12?RCM?
1 21200 [6.2] 6000 [1.8]
47500 [13.9] 17.5 12
1200 [566] 73
2 35250 [10.3] 12250 [3.6] 1575 [743] 74
RGJF-09?ZCM?
1 21200 [6.2] 6000 [1.8]
47500 [13.9] 17 12
1225 [578] 73
2 35150 [10.3] 12350 [3.6] 1600 [755] 74
RGJF-10?ZCM?
1 21050 [6.2] 5950 [1.7]
47500 [13.9] 16.5 11.5
1200 [566] 73
2 34950 [10.2] 12550 [3.7] 1600 [755] 74
RGJF-12?RCM?
1 21200 [6.2] 6000 [1.8]
47500 [13.9] 17.5 12
1200 [566] 73
2 35250 [10.3] 12250 [3.6] 1575 [743] 74
RGLE-10?BRM?
1 21400 [6.3] 6000 [1.8]
48000 [14.1] 17.5 12.5
1200 [566] 73
2 35400 [10.4] 12600 [3.7] 1600 [755] 74
RGLE-12?ARM?
1 21350 [6.3] 6050 [1.8]
48000 [14.1] 17.5 12.5
1225 [578] 73
2 35400 [10.4] 12600 [3.7] 1600 [755] 74
RGPE-07?BRQ?
1 20950 [6.1] 5850 [1.7]
47000 [13.8] 17.5 12.5
1050 [495] 73
2 34800 [10.2] 12200 [3.6] 1400 [661] 74
RGPE-10?BRM?
1 21400 [6.3] 6000 [1.8]
47500 [13.9] 17 12
1225 [578] 73
2 35250 [10.3] 12250 [3.6] 1625 [767] 74
RGPE-12?ARM?
1 21400 [6.3] 6000 [1.8]
48000 [14.1] 17.5 12.5
1200 [566] 73
2 35400 [10.4] 12600 [3.7] 1625 [767] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series