Specification Sheet
34
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
048JEC
RCFN-H*4824
RGRM-07?YBG?
1 20400 [6.0] 5800 [1.7]
46000 [13.5] 16 11
1050 [495] 73
2 33950 [9.9] 12050 [3.5] 1400 [661] 74
RGRM-09?ZAJ?
1 20750 [6.1] 5850 [1.7]
47000 [13.8] 17 12
1075 [507] 73
2 34550 [10.1] 12450 [3.6] 1400 [661] 74
RGRM-10?ZAJ?
1 20600 [6.0] 5800 [1.7]
47000 [13.8] 17 12
1025 [484] 73
2 34550 [10.1] 12450 [3.6] 1425 [672] 74
RGRM-12?RAJ?
1 20900 [6.1] 5900 [1.7]
47000 [13.8] 17.5 12
1075 [507] 73
2 34650 [10.2] 12350 [3.6] 1425 [672] 74
RGTM-07?RBG?
1 21550 [6.3] 6050 [1.8]
47500 [13.9] 16.5 11.5
1325 [625] 73
2 35250 [10.3] 12250 [3.6] 1675 [790] 74
RGTM-09?ZAJ?
1 21400 [6.3] 6000 [1.8]
47500 [13.9] 16.5 11.5
1250 [590] 73
2 34950 [10.2] 12550 [3.7] 1600 [755] 74
RGTM-10?RBJ?
1 21350 [6.3] 6050 [1.8]
48000 [14.1] 16.5 12
1275 [602] 73
2 35400 [10.4] 12600 [3.7] 1675 [790] 74
ROCA-070E04
1 21050 [6.2] 5950 [1.7]
46500 [13.6] 15.5 12
1200 [566] 73
2 34550 [10.1] 11950 [3.5] 1400 [661] 74
ROLA-070E04
1 21050 [6.2] 5950 [1.7]
47500 [13.9] 16 11.5
1175 [554] 73
2 34950 [10.2] 12550 [3.7] 1600 [755] 74
ROLA-115E05
1 21200 [6.2] 6000 [1.8]
47500 [13.9] 16.5 12
1200 [566] 73
2 35300 [10.3] 12200 [3.6] 1600 [755] 74
RCFN-H*4824+RXMD-C06 Coil Only
1 21400 [6.3] 5100 [1.5]
47500 [13.9] 15.5 12
1200 [566] 73
2 34800 [10.2] 12700 [3.7] 1600 [755] 74
RCQD-4821
RGFE-09?ZCM?
1 19850 [5.8] 5750 [1.7]
45500 [13.3] 16 11
1200 [566] 73
2 33400 [9.8] 12100 [3.5] 1600 [755] 74
RGFE-10?ZCM?
1 20000 [5.9] 5800 [1.7]
45500 [13.3] 15.5 11
1225 [578] 73
2 33400 [9.8] 12100 [3.5] 1600 [755] 74
RGFG-09?ZCM?
1 18450 [5.4] 6550 [1.9]
45500 [13.3] 16.5 11
775 [366] 73
2 33300 [9.8] 12200 [3.6] 1600 [755] 74
RGFG-10?ZCM?
1 20400 [6.0] 5600 [1.6]
44500 [13.0] 16.5 12
1050 [495] 73
2 29950 [8.8] 14550 [4.3] 1275 [602] 74
RGJF-09?ZCM?
1 20200 [5.9] 5800 [1.7]
45500 [13.3] 16 11.5
1225 [578] 73
2 33550 [9.8] 11950 [3.5] 1600 [755] 74
RGJF-10?ZCM?
1 20050 [5.9] 5750 [1.7]
45500 [13.3] 16 11.5
1200 [566] 73
2 33550 [9.8] 11950 [3.5] 1600 [755] 74
RGPE-07?BRQ?
1 20150 [5.9] 5850 [1.7]
46000 [13.5] 16.5 12
1225 [578] 73
2 33850 [9.9] 12150 [3.6] 1600 [755] 74
RGPE-10?BRM?
1 20150 [5.9] 5850 [1.7]
46000 [13.5] 16.5 12
1225 [578] 73
2 33850 [9.9] 12150 [3.6] 1625 [767] 74
RGRM-07?YBG?
1 19300 [5.7] 5500 [1.6]
44500 [13.0] 15.5 10.5
1050 [495] 73
2 32500 [9.5] 12000 [3.5] 1400 [661] 74
RGRM-09?ZAJ?
1 19450 [5.7] 5550 [1.6]
45000 [13.2] 16.5 11.5
1075 [507] 73
2 33100 [9.7] 11900 [3.5] 1400 [661] 74
RGRM-10?ZAJ?
1 19450 [5.7] 5550 [1.6]
45000 [13.2] 16.5 11.5
1025 [484] 73
2 33050 [9.7] 11950 [3.5] 1425 [672] 74
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series