Specification Sheet
36
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
048JEC
RCQD-4824 ROLA-115E05
1 20800 [6.1] 6000 [1.8]
46000 [13.5] 16 12
1200 [566] 73
2 34050 [10.0] 11950 [3.5] 1600 [755] 74
RCQD-4824+RXMD-C06 Coil Only
1 21400 [6.3] 4500 [1.3]
46000 [13.5] 14.5 11.5
1200 [566] 73
2 33600 [9.8] 12400 [3.6] 1600 [755] 74
RCSL-H*4824 RHPL-HM4824
1 18800 [5.5] 7200 [2.1]
46000 [13.5] 17 12.5
1250 [590] 73
2 30900 [9.1] 15100 [4.4] 1625 [767] 74
060JEC
RCSN-H*6024
➀
RHPN-HM6024
1 23600 [6.9] 8800 [2.6]
57000 [16.7] 18 12
1050 [495] 67
2 39100 [11.5] 17900 [5.2] 1700 [802] 72
1 - dehumid 22100 [6.5] 10300 [3.0] 925 [437]
2 - dehumid 36200 [10.6] 20800 [6.1] 1325 [625]
RCFL-H*6024
RGFE-09?ZCM?
1 23500 [6.9] 9100 [2.7]
56000 [16.4] 16 11
1200 [566] 67
2 38250 [11.2] 17750 [5.2] 1600 [755] 72
RGFE-10?ZCM?
1 23450 [6.9] 9150 [2.7]
55500 [16.3] 15.5 11
1225 [578] 67
2 38100 [11.2] 17400 [5.1] 1600 [755] 72
RGFE-12?RCM?
1 23600 [6.9] 9200 [2.7]
56500 [16.6] 16 11.5
1225 [578] 67
2 38550 [11.3] 17950 [5.3] 1625 [767] 72
RGFG-09?ZCM?
1 22550 [6.6] 9250 [2.7]
56500 [16.6] 16 10.5
975 [460] 67
2 41050 [12.0] 15450 [4.5] 1950 [920] 72
RGFG-10?ZCM?
1 24300 [7.1] 8300 [2.4]
56000 [16.4] 15.5 11
1200 [566] 67
2 37800 [11.1] 18200 [5.3] 1650 [779] 72
RGFG-12?RCM?
1 24550 [7.2] 8250 [2.4]
56000 [16.4] 16 11.5
1225 [578] 67
2 37450 [11.0] 18550 [5.4] 1625 [767] 72
RGGE-09?ZCM?
1 23600 [6.9] 9200 [2.7]
56000 [16.4] 16 11.5
1225 [578] 67
2 38400 [11.3] 17600 [5.2] 1600 [755] 72
RGGE-10?ZCM?
1 23450 [6.9] 9150 [2.7]
56000 [16.4] 16 11.5
1200 [566] 67
2 38250 [11.2] 17750 [5.2] 1600 [755] 72
RGGE-12?RCM?
1 24050 [7.0] 9350 [2.7]
56500 [16.6] 16 11.5
1375 [649] 67
2 38750 [11.4] 17750 [5.2] 1750 [826] 72
RGJF-09?ZCM?
1 23600 [6.9] 9200 [2.7]
56000 [16.4] 16 11.5
1225 [578] 67
2 38400 [11.3] 17600 [5.2] 1600 [755] 72
RGJF-10?ZCM?
1 23450 [6.9] 9150 [2.7]
56000 [16.4] 16 11.5
1200 [566] 67
2 38250 [11.2] 17750 [5.2] 1600 [755] 72
RGJF-12?RCM?
1 24050 [7.0] 9350 [2.7]
56500 [16.6] 16 11.5
1375 [649] 67
2 38750 [11.4] 17750 [5.2] 1750 [826] 72
RGPE-10?BRM?
1 23800 [7.0] 9200 [2.7]
56500 [16.6] 16.5 11.5
1225 [578] 67
2 38650 [11.3] 17850 [5.2] 1625 [767] 72
RGPE-12?ARM?
1 23600 [6.9] 9200 [2.7]
56500 [16.6] 16.5 12
1200 [566] 67
2 38800 [11.4] 17700 [5.2] 1625 [767] 72
RGRM-10?ZAJ?
1 23400 [6.9] 8800 [2.6]
55500 [16.3] 16 11
1150 [543] 67
2 37950 [11.1] 17550 [5.1] 1600 [755] 72
RGRM-12?RAJ?
1 23850 [7.0] 8950 [2.6]
56000 [16.4] 16 11.5
1225 [578] 67
2 38350 [11.2] 17650 [5.2] 1625 [767] 72
RGTM-07?RBG?
1 23900 [7.0] 9300 [2.7]
56500 [16.6] 16 11.5
1325 [625] 67
2 38700 [11.3] 17800 [5.2] 1675 [790] 72
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series