Specification Sheet

37
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
060JEC
RCFL-H*6024
RGTM-09?ZAJ?
1 23600 [6.9] 9200 [2.7]
56000 [16.4] 16 11.5
1250 [590] 67
2 38200 [11.2] 17800 [5.2] 1600 [755] 72
RGTM-10?RBJ?
1 23750 [7.0] 9250 [2.7]
56500 [16.6] 16 11.5
1275 [602] 67
2 38600 [11.3] 17900 [5.2] 1675 [790] 72
ROLA-070E04
1 23700 [6.9] 8900 [2.6]
55500 [16.3] 15.5 11.5
1175 [554] 67
2 38200 [11.2] 17300 [5.1] 1600 [755] 72
ROLA-115E05
1 23850 [7.0] 8950 [2.6]
56000 [16.4] 16 11.5
1200 [566] 67
2 38550 [11.3] 17450 [5.1] 1600 [755] 72
RCFL-H*6024+RXMD-C06 Coil Only
1 22400 [6.6] 9000 [2.6]
56500 [16.6] 15 11.5
1250 [590] 67
2 38500 [11.3] 18000 [5.3] 1675 [790] 72
RCFN-H*6024
RGFE-09?ZCM?
1 23700 [6.9] 8900 [2.6]
55500 [16.3] 16 11
1200 [566] 67
2 38250 [11.2] 17250 [5.1] 1600 [755] 72
RGFE-10?ZCM?
1 23650 [6.9] 8950 [2.6]
55500 [16.3] 16 11
1225 [578] 67
2 38100 [11.2] 17400 [5.1] 1600 [755] 72
RGFE-12?RCM?
1 23850 [7.0] 8950 [2.6]
56000 [16.4] 16.5 11.5
1225 [578] 67
2 38350 [11.2] 17650 [5.2] 1625 [767] 72
RGFG-09?ZCM?
1 24400 [7.1] 8200 [2.4]
55500 [16.3] 16 11
1200 [566] 67
2 36950 [10.8] 18550 [5.4] 1600 [755] 72
RGFG-10?ZCM?
1 24400 [7.1] 8200 [2.4]
56000 [16.4] 16 11
1200 [566] 67
2 37850 [11.1] 18150 [5.3] 1650 [779] 72
RGFG-12?RCM?
1 24800 [7.3] 8000 [2.3]
56000 [16.4] 16.5 11.5
1225 [578] 67
2 37600 [11.0] 18400 [5.4] 1625 [767] 72
RGGE-09?ZCM?
1 23850 [7.0] 8950 [2.6]
56000 [16.4] 16.5 11.5
1225 [578] 67
2 38400 [11.3] 17600 [5.2] 1600 [755] 72
RGGE-10?ZCM?
1 23700 [6.9] 8900 [2.6]
55500 [16.3] 16 11
1200 [566] 67
2 38250 [11.2] 17250 [5.1] 1600 [755] 72
RGGE-12?RCM?
1 23250 [6.8] 8750 [2.6]
57000 [16.7] 16.5 11
1000 [472] 67
2 39050 [11.4] 17950 [5.3] 1950 [920] 72
RGJF-09?ZCM?
1 24300 [7.1] 9100 [2.7]
56000 [16.4] 15.5 11
1400 [661] 67
2 38500 [11.3] 17500 [5.1] 1775 [838] 72
RGJF-10?ZCM?
1 24100 [7.1] 9100 [2.7]
56000 [16.4] 15 11
1400 [661] 67
2 38500 [11.3] 17500 [5.1] 1775 [838] 72
RGJF-12?RCM?
1 24250 [7.1] 9150 [2.7]
56500 [16.6] 16 11.5
1375 [649] 67
2 38800 [11.4] 17700 [5.2] 1750 [826] 72
RGPE-07?BRQ?
1 24000 [7.0] 9000 [2.6]
56000 [16.4] 16.5 11.5
1225 [578] 67
2 38500 [11.3] 17500 [5.1] 1600 [755] 72
RGPE-10?BRM?
1 24000 [7.0] 9000 [2.6]
56500 [16.6] 16.5 11.5
1225 [578] 67
2 38650 [11.3] 17850 [5.2] 1625 [767] 72
RGPE-12?ARM?
1 23800 [7.0] 9000 [2.6]
56500 [16.6] 17 12
1200 [566] 67
2 38800 [11.4] 17700 [5.2] 1625 [767] 72
RGRM-12?RAJ?
1 23850 [7.0] 8950 [2.6]
56000 [16.4] 16 11.5
1225 [578] 67
2 38350 [11.2] 17650 [5.2] 1625 [767] 72
RGTM-07?RBG?
1 24150 [7.1] 9050 [2.7]
56500 [16.6] 16 11.5
1325 [625] 67
2 38650 [11.3] 17850 [5.2] 1675 [790] 72
RGTM-09?ZAJ?
1 24000 [7.0] 9000 [2.6]
55500 [16.3] 16 11.5
1250 [590] 67
2 38200 [11.2] 17300 [5.1] 1600 [755] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series