Specification Sheet

38
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
060JEC
RCFN-H*6024
RGTM-10?RBJ?
1 23950 [7.0] 9050 [2.7]
56500 [16.6] 16.5 11.5
1275 [602] 67
2 38800 [11.4] 17700 [5.2] 1675 [790] 72
ROLA-070E04
1 23700 [6.9] 8900 [2.6]
55500 [16.3] 15.5 11.5
1175 [554] 67
2 38200 [11.2] 17300 [5.1] 1600 [755] 72
ROLA-115E05
1 23850 [7.0] 8950 [2.6]
56000 [16.4] 16 11.5
1200 [566] 67
2 38550 [11.3] 17450 [5.1] 1600 [755] 72
RCFN-H*6024+RXMD-C06 Coil Only
1 24400 [7.1] 7900 [2.3]
56500 [16.6] 15 11.5
1250 [590] 67
2 38500 [11.3] 18000 [5.3] 1680 [793] 72
RCQD-6024
RBHM-26J*
1 22500 [6.6] 9300 [2.7]
54500 [16.0] 16.5 12
1275 [602] 67
2 36800 [10.8] 17700 [5.2] 1700 [802] 72
RGFE-09?ZCM?
1 21550 [6.3] 9250 [2.7]
52500 [15.4] 15 10.5
1200 [566] 67
2 35500 [10.4] 17000 [5.0] 1600 [755] 72
RGFE-10?ZCM?
1 21550 [6.3] 9250 [2.7]
52000 [15.2] 15 10.5
1225 [578] 67
2 35350 [10.4] 16650 [4.9] 1600 [755] 72
RGFE-12?RCM?
1 21700 [6.4] 9300 [2.7]
52500 [15.4] 15.5 11
1225 [578] 67
2 35600 [10.4] 16900 [5.0] 1625 [767] 72
RGFG-09?ZCM?
1 22150 [6.5] 8450 [2.5]
52000 [15.2] 15 10.5
1200 [566] 67
2 34100 [10.0] 17900 [5.2] 1600 [755] 72
RGFG-10?ZCM?
1 22150 [6.5] 8450 [2.5]
52500 [15.4] 15 10.5
1200 [566] 67
2 35150 [10.3] 17350 [5.1] 1650 [779] 72
RGFG-12?RCM?
1 22600 [6.6] 8400 [2.5]
52500 [15.4] 15 11
1225 [578] 67
2 34800 [10.2] 17700 [5.2] 1625 [767] 72
RGJF-09?ZCM?
1 21700 [6.4] 9300 [2.7]
52500 [15.4] 15 11
1225 [578] 67
2 35650 [10.4] 16850 [4.9] 1600 [755] 72
RGJF-10?ZCM?
1 21550 [6.3] 9250 [2.7]
52500 [15.4] 15 10.5
1200 [566] 67
2 35500 [10.4] 17000 [5.0] 1600 [755] 72
RGJF-12?RCM?
1 21700 [6.4] 9300 [2.7]
52500 [15.4] 15.5 11
1200 [566] 67
2 35800 [10.5] 16700 [4.9] 1575 [743] 72
RGPE-07?BRQ?
1 21650 [6.3] 9350 [2.7]
52500 [15.4] 15.5 11
1225 [578] 67
2 35750 [10.5] 16750 [4.9] 1600 [755] 72
RGPE-10?BRM?
1 21650 [6.3] 9350 [2.7]
53000 [15.5] 15.5 11
1225 [578] 67
2 35900 [10.5] 17100 [5.0] 1625 [767] 72
RGPE-12?ARM?
1 21700 [6.4] 9300 [2.7]
53000 [15.5] 16 11
1200 [566] 67
2 36050 [10.6] 16950 [5.0] 1625 [767] 72
RGRM-09?ZAJ?
1 21900 [6.4] 9100 [2.7]
52500 [15.4] 14.5 10.5
1225 [578] 67
2 35600 [10.4] 16900 [5.0] 1625 [767] 72
RGRM-10?ZAJ?
1 21600 [6.3] 9000 [2.6]
52500 [15.4] 15 10.5
1150 [543] 67
2 35400 [10.4] 17100 [5.0] 1600 [755] 72
RGRM-12?RAJ?
1 21850 [6.4] 9150 [2.7]
53000 [15.5] 15 11
1225 [578] 67
2 35850 [10.5] 17150 [5.0] 1625 [767] 72
ROLA-070E04
1 21550 [6.3] 9250 [2.7]
53000 [15.5] 14.5 10.5
1175 [554] 67
2 35450 [10.4] 17550 [5.1] 1600 [755] 72
ROLA-115E05
1 21700 [6.4] 9300 [2.7]
53000 [15.5] 15 11
1200 [566] 67
2 35800 [10.5] 17200 [5.0] 1600 [755] 72
RCQD-6024+RXMD-C06 Coil Only
1 20400 [6.0] 9100 [2.7]
53000 [15.5] 14 11
1275 [602] 67
2 35600 [10.4] 17400 [5.1] 1700 [802] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series