Specification Sheet

7
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEC
RCFL-H*2621
RGJF-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGJF-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGLE-07?AMK?
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RGPE-05?BMK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGPE-07?AMK?
1 15000 [4.4] 6000 [1.8]
25800 [7.6] 18 13
625 [295] 71
2 19300 [5.7] 6500 [1.9] 825 [389] 74
RGRM-04?MAE?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGRM-06?MAE?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGRM-07?MAE?
1 14800 [4.3] 6000 [1.8]
25400 [7.4] 17.5 13
625 [295] 71
2 18900 [5.5] 6500 [1.9] 850 [401] 74
RGTM-06?MAE?
1 15800 [4.6] 5800 [1.7]
25600 [7.5] 18 13
750 [354] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
ROCA-070E03
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
ROLA-070E03
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RCFL-H*2621+RXMD-C06 Coil Only
1 14400 [4.2] 6000 [1.8]
25200 [7.4] 15.5 12.5
625 [295] 71
2 18700 [5.5] 6500 [1.9] 825 [389] 74
RCFN-H*2417
RGFE-06?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGFE-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGFG-06?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGFG-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 850 [401] 74
RGGE-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGGE-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGJF-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGJF-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGLE-07?AMK?
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RGPE-05?BMK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling
Air
Performance Data
RASL- JEC Series