Specifications

TM024 Premier Loline Solar Drain back Service Instructions REV: A
D.O.I: 12/12/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
4
Specifications
Specification 590, 591 & 596 Models
Storage capacity 270 Litres
Temperature setting 60ºC
TPR valve setting 1000kPa
Solar circuit relief valve 200kPa
Max supply pressure 800kPa (680kPa with ECV)
Min supply pressure 200kPa
Water connections- tank Inlet RP¾/20, Outlet RP¾ /20
Water connections- collector Hot pipe ½” BSP, Cold pipe ½” BSP
Collector(s) type S200 or T200
Supply voltage 220 – 250 Volts AC 50Hz
Solar circuit fluid *4.5 Litres propylene glycol / 11.5 Litres water
Anodes 2 X 1153mm
Solar circuit pump 127.8 ohms
Solar circuit aux pump (optional) 127.8 ohms
* Approximate propylene glycol / water ratio. Refer to ‘Commissioning Procedure’ on page
57 for more information.
Power Consumption
Solar controller 3 Watts Constant load
Solar pump
165 Watts
Maximum load at solar heating cycle start up
(for approximately two (2) minutes)
50 Watts Average load during the solar heating cycle
Heating unit
(591 models only)
2.4kW, 3.6kW
or 4.8kW
Consumption when booster heating unit is operating
depending upon model
Gas Booster
(596 models only)
146W When anti frost device is activated
Electric Booster Specifications (591 models only)
Heating unit rating depending upon model 2.4kW 3.6kW 4.8kW
Amps 10 15 20
Element circuit resistance (ohms) 22 – 26 15 – 17 11 - 13
Booster capacity 125 litres
Booster temperature setting 60ºC
Gas Booster Specifications (596 models only)
Input 199mJ
Booster capacity 26L/min
Booster temperature setting 60ºC
For complete gas booster specifications refer to Integrity 26 Service Manual TM023.