Specifications

TM024 Premier Loline Solar Drain back Service Instructions REV: A
D.O.I: 12/12/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
42
Voltages up to 240 volts will be present within the water heater, take care
not to touch wiring terminals. Use an insulated tool when operating the DIP
switch or MIN and MAX buttons.
1. Remove the front cover from the water heater.
2. Turn DIP SWITCHES 3 and 4 on (up position) on the I.C. Board. The current preset
temperature is displayed on the LED.
3. Press the MIN or MAX button, located under the DIP Switches, until 60ºC is displayed.
4. Turn DIP SWITCHES 3 and 4 off (down position). The temperature display is now
turned off.
5. Refit the front cover to the water heater.
Electrical Insulation Testing
There are three basic test procedures that should be carried out when the operation and
function of a Premier Loline water heater’s electrical system is in doubt.
Wear Personal Protective Equipment when conducting step 1 of these
procedures to reduce the risk of electric shock. Refer to Rheem safety
procedure on electrical testing.
590 & 596 Models
Procedure 1: Insulation resistance of the water heater Neutral Circuit. (Reading not
to be below 0.66 Mega ohm).
1. Isolate power to the water heater by switching off at power point and unplugging
appliance 3 pin plug from power point. Confirm with multi-meter across terminal
block Active and Neutral, then Active and Earth, then Neutral and Earth that
voltage is not present.
2. Connect megger leads to the Neutral of the water heater wiring and Earth.
3. Operate megger. A reading above 0.66 Mega ohm should be obtained.
4. If a reading below 0.66 Mega ohm is indicated, all component parts will need to be
individually tested to locate the fault. Refer to Fault Finding Chart 1.4 on page 30.
Procedure 2: Insulation resistance of the water heater Active Circuit (reading not to
be below 0.66 mega-ohm).
6. Connect megger leads to the Active of the water heater wiring and Earth.
7. Operate megger. A reading above 0.66 Mega ohm should be obtained.
8. If a reading below 0.66 Mega ohm is indicated, all component parts will need to be
individually tested to locate the fault. Refer to Fault Finding Chart 1.4 on page 30.
Procedure 3: To check “Continuity” of the water heater electrical circuit.
9. Set megger to resistance scale or multimeter to x1 resistance scale.
10. Measure between the Active and Neutral terminals on the power supply terminal block
located behind the upper electrical access cover. The resistance should be
approximately 1.82 kilo ohms for 590 models and 51.5 ohms for 596 models. If a
reading outside these resistance values is obtained, all electrical component parts will
need to be individually tested to locate the fault. Refer to Specifications table on page 4
for indicative resistance values of components.
11. Plug appliance 3 pin plug back into power point and switch on power point. Note: If
continuing with any diagnostic procedures do not perform this step.