Specification

Hybrid Water Heater Installation Guidelines to Provide Optimal Efficiency
3
05/20 FORM NO. THD-PPEH5-30SO Rev. 1
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating 1115 Northmeadow Parkway, Suite 100
Roswell, Georgia 30076 www.rheem.com
Room size: Larger than 700 ft
3
(e.g. 7' x 10' x 10').
Requirements: No additional ventilation needed.
Heater: Not Ducted
24”
12” Max
Air exhaust
Door
.75”
Room size: Any size room
Requirements: No additional ventilation needed.
Heater: Ducted with inlet AND outlet duct
Room size: Any size room
Requirements: Air gap under door equal to 18 in
2
(0.75” clearance)
Heater: Ducted with inlet OR outlet duct
Room size: Smaller than 700 ft
3
(e.g. 7' x 10' x 10').
Requirements: Full louvered door OR two louvers
top and bottom. See below.
Heater: Not Ducted
24”
.75”
Room: Small Closet
Requirements: * Air gap under door equal to 18 in
2
(0.75” clearance).
* Louver must be located the same height on door as
the air exhaust on heater.
* Heater air exhaust must be positioned towards louver
within one foot of door.
Heater: Not ducted